LCSC Electronics logoLCSC Electronics svg logo
Sign In
USD
HGSEMI 74HC192M/TR product image
  • 74HC192M/TR thumbnail 1
  • 74HC192M/TR thumbnail 2
  • 74HC192M/TR thumbnail 3
  • Pinout Diagram
  • Footprint Diagram
Images for reference only

HGSEMI 74HC192M/TRRoHS

Manufacturer
HGSEMIAsian Brands
MPN
74HC192M/TR
LCSC Part #
C5310771
Packaging
SOP-16
Customer #
Key Attributes
Presettable synchronous BcD decade up/down counter
Datasheetpdf iconHGSEMI 74HC192M/TR
In-Stock: 630
630 In stock, ships now
Add to BOM List
QtyUnit PriceTotal Amount
5+$ 0.1714$ 0.86
50+$ 0.1355$ 6.78
150+$ 0.1202$ 18.03
500+$ 0.101$ 50.50
2,500+$ 0.0881$ 220.25
5,000+$ 0.083$ 415.00
Standard Packaging2500/Full Reel
Better price for more quantity?
$

Products Specifications

Show similar products (0) >
TypeDescription
CategoryIntegrated Circuits (ICs)/Logic/Counters, Dividers
ManufacturerHGSEMI
PackagingSOP-16
Voltage - Supply2V~6V
DirectionUp Counter;Down Counter
Trigger TypeRising Edge
TimingSynchronous
Operating Temperature-40℃~+85℃
ResetAsynchronous
Propagation Delay20ns@5V,15pF
Count Rate40MHz
FeaturesSynchronous counting;Asynchronous parallel load;Reset function;Cascade counter

Additional Information

TypeDetails
Minimum5
Multiple5
Standard Packaging2500
Sales UnitPiece

Introduction

AI Translation

The 74HC/HCT192 are high-speed Si-gate CMOS devices and are pin compatible with low power Schottky TTL (LSTTL). They are specified in compliance with JEDEC standard no. 7A. The 74HC/HCT192 are synchronous BCD up/down counters. Separate up/down clocks, CPU and CPD respectively, simplify operation. The outputs change state synchronously with the LOW-to-HIGH transition of either clock input. If the CPU clock is pulsed while CPD is held HIGH, the device will count up. If the CPD clock is pulsed while CPU is held HIGH, the device will count down. Only one clock input can be held HIGH at any time, or erroneous operation will result. The device can be cleared at any time by the asynchronous master reset input (MR); it may also be loaded in parallel by activating the asynchronous parallel load input (PL (overline)). The “192” contains four master-slave JK flip-flops with the necessary steering logic to provide the asynchronous reset, load, and synchronous count up and count down functions. Each flip-flop contains JK feedback from slave to master, such that a LOW-to-HIGH transition on the CPD input will decrease the count by one, while a similar transition on the CPU input will advance the count by one. One clock should be held HIGH while counting with the other, otherwise the circuit will either count by two’s or not at all, depending on the state of the first flip-flop, which cannot toggle as long as either clock input is LOW. Applications requiring reversible operation must make the reversing decision while the activating clock is HIGH to avoid erroneous counts. The terminal count up (TCU (overline)) and terminal count down (TCD (overline)) outputs are normally HIGH. When the circuit has reached the maximum count state of 9, the next HIGH-to-LOW transition of CPU will cause TCU (overline) to go LOW. TCU (overline) will stay LOW until CPU goes HIGH again, duplicating the count up clock. Likewise, the TCD (overline) output will go LOW when the circuit is in the zero state and the CPD goes LOW. The terminal count outputs can be used as the clock input signals to the next higher order circuit in a multistage counter, since they duplicate the clock wave forms. Multistage counters will not be fully synchronous, since there is a slight delay time difference added for each stage that is added. The counter may be preset by the asynchronous parallel load capability of the circuit. Information present on the parallel data inputs [D0 to D3] is loaded into the counter and appears on the outputs (Q0 to Q3) regardless of the conditions of the clock inputs when the parallel load (PL (overline)) input is LOW. A HIGH level on the master reset (MR) input will disable the parallel load gates, override both clock inputs and set all outputs (Q0 to Q3) LOW. If one of the clock inputs is LOW during and after a reset or load operation, the next LOW-to-HIGH transition of that clock will be interpreted as a legitimate signal and will be counted.

Features

AI Translation
  • Synchronous reversible counting
  • Asynchronous parallel load
  • Asynchronous reset
  • Expandable without external logic
  • Output capability: standard ICC category: MSI