ATLAS ENV-40-DOX
| Manufacturer | |
| MPN | ENV-40-DOX |
| LCSC Part # | C17561205 |
| Packaging | - |
| Customer # | |
| Key Attributes | +1℃~+60℃ Environmental Testers RoHS |
| Datasheet |
Products Specifications
Show similar products (0) >| Type | Description | |
|---|---|---|
| Category | Measuring & Inspecting/Inspecting/Environmental Testers | |
| Manufacturer | ATLAS | |
| Packaging | - | |
| Detection Temperature Range | +1℃~+60℃ | |
| working temperature | - | |
| Accuracy | - |
Additional Information
| Type | Details |
|---|---|
| Minimum | 1 |
| Multiple | 1 |
| Standard Packaging | 1 |
| Sales Unit | Piece |
| EDA Models | EasyEDA Model |
Introduction
This dissolved oxygen probe can read dissolved oxygen with a measurement range of 0 - 100 mg/L, accuracy of +/- 0.05 mg/L, response time of approximately 0.3 mg/L per second, temperature range of 1 - 60°C, maximum pressure of 3447 kPa (500 PSI), maximum depth of 352 m (1157 ft), connector of male SMA/male BNC (optional), cable length of 1 meter, no internal temperature sensor, time before recalibration of approximately 1 year, expected lifespan of approximately 4 years, and maintenance interval of approximately 18 months. This dissolved oxygen probe can be fully submerged in fresh or salt water up to the SMA connector and can be soaked indefinitely.
Features
- Measurement Range: 0 - 100 mg/L
- Accuracy: +/- 0.05 mg/L
- Response Time: ~0.3 mg/L per second
- Temperature Range: 1 - 60°C
- Maximum Pressure: 3447 kPa (500 PSI)
- Maximum Depth: 352 m (1157 ft)
- Connector: Male SMA / Male BNC (optional)
- Cable Length: 1 m
- Internal Temperature Sensor: None
- Time Before Recalibration: ~1 year
- Expected Lifespan: ~4 years
- Maintenance Interval: ~18 months
Applications
- Standard laboratory use
- Field use
- Hydroponics
- Aquaculture
- Brewing
- Environmental monitoring
| Qty | Unit Price(Reference Only) | Total Amount |
|---|---|---|
| 1+ | $ 282.7168 | $ 282.72 |
| 200+ | $ 265.5278 | $ 53105.56 |
| 500+ | $ 256.6551 | $ 128327.55 |
| 1,000+ | $ 252.2702 | $ 252270.20 |
Standard Packaging1/Full Bag | ||
Products Specifications
Show similar products (0) >| Type | Description | |
|---|---|---|
| Category | Measuring & Inspecting/Inspecting/Environmental Testers | |
| Manufacturer | ATLAS | |
| Packaging | - | |
| Detection Temperature Range | +1℃~+60℃ | |
| working temperature | - | |
| Accuracy | - |
Additional Information
| Type | Details |
|---|---|
| Minimum | 1 |
| Multiple | 1 |
| Standard Packaging | 1 |
| Sales Unit | Piece |
| EDA Models | EasyEDA Model |
Introduction
This dissolved oxygen probe can read dissolved oxygen with a measurement range of 0 - 100 mg/L, accuracy of +/- 0.05 mg/L, response time of approximately 0.3 mg/L per second, temperature range of 1 - 60°C, maximum pressure of 3447 kPa (500 PSI), maximum depth of 352 m (1157 ft), connector of male SMA/male BNC (optional), cable length of 1 meter, no internal temperature sensor, time before recalibration of approximately 1 year, expected lifespan of approximately 4 years, and maintenance interval of approximately 18 months. This dissolved oxygen probe can be fully submerged in fresh or salt water up to the SMA connector and can be soaked indefinitely.
Features
- Measurement Range: 0 - 100 mg/L
- Accuracy: +/- 0.05 mg/L
- Response Time: ~0.3 mg/L per second
- Temperature Range: 1 - 60°C
- Maximum Pressure: 3447 kPa (500 PSI)
- Maximum Depth: 352 m (1157 ft)
- Connector: Male SMA / Male BNC (optional)
- Cable Length: 1 m
- Internal Temperature Sensor: None
- Time Before Recalibration: ~1 year
- Expected Lifespan: ~4 years
- Maintenance Interval: ~18 months
Applications
- Standard laboratory use
- Field use
- Hydroponics
- Aquaculture
- Brewing
- Environmental monitoring
Compliance & Export Codes
| Type | Details |
|---|---|
| RoHS | |
| ECCN | - |
| CNHTS | 9025191010 |
| USHTS | 9025194000 |
| TARIC | 9025190010 |
| CAHTS | 9025190011 |
| BRHTS | 90251910 |
| INHTS | 90251910 |
| MXHTS | 9025.19.01 |
| Type | Details |
|---|---|
| RoHS | |
| ECCN | - |
| CNHTS | 9025191010 |
| USHTS | 9025194000 |
| TARIC | 9025190010 |
| Type | Details |
|---|---|
| CAHTS | 9025190011 |
| BRHTS | 90251910 |
| INHTS | 90251910 |
| MXHTS | 9025.19.01 |