LCSC Electronics logoLCSC Electronics svg logo
Sign In
USD
6% OFF
TI ISO1050DWR product image
  • ISO1050DWR thumbnail 1
  • ISO1050DWR thumbnail 2
  • ISO1050DWR thumbnail 3
  • Pinout Diagram
  • Footprint Diagram
Images for reference only

TI ISO1050DWRRoHS

Manufacturer
MPN
ISO1050DWR
LCSC Part #
C93718
Packaging
SOIC-16-300mil
Customer #
Key Attributes
Isolated CAN Transceiver
Datasheetpdf iconTI ISO1050DWR
In-Stock: 18,701
18,701 In stock, ships now
Add to BOM List
QtyUnit PriceTotal Amount
1+$ 0.9383$ 0.8820$ 0.88
10+$ 0.7665$ 0.7206$ 7.21
30+$ 0.6806$ 0.6398$ 19.19
100+$ 0.5964$ 0.5607$ 56.07
500+$ 0.5461$ 0.5134$ 256.70
1,000+$ 0.5186$ 0.4875$ 487.50
Standard Packaging2000/Full Reel
Better price for more quantity?
$

Products Specifications

Show similar products (0) >
TypeDescription
CategoryIntegrated Circuits (ICs)/Interface/Drivers, Receivers, Transceivers
ManufacturerTI
PackagingSOIC-16-300mil
number of channels1
Operating Temperature-55℃~+105℃
Voltage - Supply (Bus)4.75V~5.25V
Voltage - Supply (Logic)3V~5.5V
CMTI(kV/us)50kV/us
FeaturesFail-safe;Bus fault detection and protection
Data Rate(Max)1Mbps
Isolation Voltage(Vrms)4243

Additional Information

TypeDetails
Minimum1
Multiple1
Standard Packaging2000
Sales UnitPiece

Introduction

AI Translation

The ISO1050 is a galvanically isolated CAN transceiver that meets the specifications of the ISO11898-2 standard. The device has the logic input and output buffers separated by a silicon oxide (SiO₂) insulation barrier that provides galvanic isolation of up to 5000 VRMS for ISO1050DW and 2500 VRMS for ISO1050DUB. Used in conjunction with isolated power supplies, the device prevents noise currents on a data bus or other circuits from entering the local ground and interfering with or damaging sensitive circuitry. As a CAN transceiver, the device provides differential transmit capability to the bus and differential receive capability to a CAN controller at signaling rates up to 1 megabit per second (Mbps). The device is designed for operation in especially harsh environments, and it features cross-wire, overvoltage and loss of ground protection from -27 V to 40 V and overtemperature shutdown, as well as -12- to 12-V common-mode range. The ISO1050 is characterized for operation over the ambient temperature range of -55°C to 105°C.

Features

AI Translation
  • Meets the Requirements of ISO11898-2
  • 5000-VRMS Isolation (ISO1050DW), 2500 VRMS Isolation (ISO1050DUB)
  • Fail-Safe Outputs
  • Low Loop Delay: 150 ns (Typical), 210 ns (Maximum)
  • 50-kV/μs Typical Transient Immunity
  • Bus-Fault Protection of –27 V to 40 V
  • Driver (TXD) Dominant Time-out Function
  • I/O Voltage Range Supports 3.3-V and 5-V Microprocessors
  • VDE Approval per DIN VDE V 0884-11:2017-01 and DIN EN 61010-1
  • UL 1577 Approved
  • CSA Approved for IEC 60950-1, IEC 61010-1, IEC 60601-1 3rd Ed (Medical)
  • TUV 5-KVRMS Reinforced Insulation Approval for EN/UL/CSA 60950-1 (ISO1050DW-Only)
  • CQC Reinforced Insulation per GB4843.1-2011 (ISO1050DW-Only)
  • Typical 25-Year Life at Rated Working Voltage

Applications

AI Translation
  • Industrial automation, control, sensors, and drive systems
  • Building and climate control (HVAC) automation
  • Security systems
  • Transportation
  • Medical
  • Telecom
  • CAN bus standards such as CANopen, DeviceNet, NMEA2000, ISO11783, CAN Kingdom