MAXIM MAX86176ENX+T
| Manufacturer | |
| MPN | MAX86176ENX+T |
| LCSC Part # | C3197546 |
| Packaging | WLP-36 |
| Customer # | |
| Key Attributes | Biometric Sensor WLP-36 Specialized Sensors RoHS |
| Datasheet |
Products Specifications
Show similar products (0) >| Type | Description | |
|---|---|---|
| Category | Sensors, Transducers/Specialized Sensors | |
| Manufacturer | MAXIM | |
| Packaging | WLP-36 | |
| Features | Integrated ADC;Interrupt output;Low-power mode;FIFO data buffer;Self-test function | |
| Sensor Type | Biometric Sensor |
Additional Information
| Type | Details |
|---|---|
| Minimum | 1 |
| Multiple | 1 |
| Standard Packaging | 2500 |
| Sales Unit | Piece |
| EDA Models | EasyEDA Model |
Introduction
The MAX86176 is a complete photoplethysmography (PPG) and electrocardiogram (ECG) analog front-end (AFE) solution for wearable applications. The MAX30005 is a complete AFE solution for ECG only. Both AFEs deliver high performance for fitness and clinical applications while offering ultra-low power consumption to extend battery life. The MAX86176 and MAX30005 both feature ECG channels, EMI filtering, internal lead biasing, AC and DC lead-off detection, right-leg drive, ultra-low power DC lead connection detection in standby mode, and extensive calibration voltages for built-in self-test. In addition, the MAX86176 includes a PPG data acquisition system supporting up to 6 LEDs and 4 photodiode inputs, fully synchronized with the ECG signal path. The MAX86176/MAX30005 can operate using either an internal or external clock. The MAX86176/MAX30005 are designed to comply with IEC 60601-2-47 ambulatory ECG monitoring standards and are suitable for challenging dry-electrode applications. The MAX86176/MAX30005 are available in a 6x6 36-bump wafer-level package (WLP) and operate over a -40°C to +85°C temperature range.
Features
- PPG (MAX86176):
- Complete dual-channel optical data acquisition system
- Ultra-low power operation for wearable devices
- Optical readout channel typical current < 11μA at 25fps
- ADC integration time: 14.6μs to 117.1μs
- Low shutdown current typical value < 1μA
- SNR up to 110dB in Avg mode with off-chip filtering
- Frame rate support: 1fps to 2kfps
- High-resolution 20-bit charge integration ADC
- Low dark current noise < 50pA (RMS)
- Excellent ambient light range and rejection: ambient light photodiode current > 100μA, ambient light rejection > 90dB at 120Hz (Avg > 2)
- ECG (MAX86176/MAX30005):
- Clinical-grade ECG AFE with high-resolution ADC: 15.6 ENOB, 0.6μV (RMS) noise over 0.05Hz to 40Hz
- Ultra-low input bias current (−40°C to +85°C)
- Input current noise: 233fA (RMS) (0.05Hz to 40Hz, TA = +25°C)
- Fully differential input architecture with CMRR > 110dB at power line frequency
- High input impedance > 1GΩ for minimal common-mode to differential-mode conversion
- High DC offset range ±1300mV (typical 1.8V), compatible with various electrode types
- High AC dynamic range > 90mV (P-P) to prevent saturation during motion
- ECG biopotential channel applicable to select EEG applications
- Higher gain range available (480V/V, 960V/V)
- Low input-referred voltage and current noise, compatible with small dry electrodes
- System:
- Shutdown current typical value: 0.5μA
- 256-word FIFO for ECG and PPG
- True synchronous ECG and PPG data from dedicated signal paths
- Two fully configurable interrupts
- High-speed SPI or I²C interface
- Compact 2.728mm × 2.708mm WLP package
Applications
- Wearable devices for fitness, wellness, and medical applications with clinical-grade accuracy
- Suitable for wrist, finger, ear, and other body locations
- Single-lead event monitors for atrial fibrillation (A-Fib) and other arrhythmia detection
- Single-lead wireless patches for home/in-hospital monitoring
- Chest strap heart rate monitors for fitness applications
| Qty | Unit Price | Total Amount |
|---|---|---|
| 1+ | $ 22.8566 | $ 22.86 |
| 30+ | $ 21.7855 | $ 653.57 |
Standard Packaging2500/Full Reel | ||
Products Specifications
Show similar products (0) >| Type | Description | |
|---|---|---|
| Category | Sensors, Transducers/Specialized Sensors | |
| Manufacturer | MAXIM | |
| Packaging | WLP-36 | |
| Features | Integrated ADC;Interrupt output;Low-power mode;FIFO data buffer;Self-test function | |
| Sensor Type | Biometric Sensor |
Additional Information
| Type | Details |
|---|---|
| Minimum | 1 |
| Multiple | 1 |
| Standard Packaging | 2500 |
| Sales Unit | Piece |
| EDA Models | EasyEDA Model |
Introduction
The MAX86176 is a complete photoplethysmography (PPG) and electrocardiogram (ECG) analog front-end (AFE) solution for wearable applications. The MAX30005 is a complete AFE solution for ECG only. Both AFEs deliver high performance for fitness and clinical applications while offering ultra-low power consumption to extend battery life. The MAX86176 and MAX30005 both feature ECG channels, EMI filtering, internal lead biasing, AC and DC lead-off detection, right-leg drive, ultra-low power DC lead connection detection in standby mode, and extensive calibration voltages for built-in self-test. In addition, the MAX86176 includes a PPG data acquisition system supporting up to 6 LEDs and 4 photodiode inputs, fully synchronized with the ECG signal path. The MAX86176/MAX30005 can operate using either an internal or external clock. The MAX86176/MAX30005 are designed to comply with IEC 60601-2-47 ambulatory ECG monitoring standards and are suitable for challenging dry-electrode applications. The MAX86176/MAX30005 are available in a 6x6 36-bump wafer-level package (WLP) and operate over a -40°C to +85°C temperature range.
Features
- PPG (MAX86176):
- Complete dual-channel optical data acquisition system
- Ultra-low power operation for wearable devices
- Optical readout channel typical current < 11μA at 25fps
- ADC integration time: 14.6μs to 117.1μs
- Low shutdown current typical value < 1μA
- SNR up to 110dB in Avg mode with off-chip filtering
- Frame rate support: 1fps to 2kfps
- High-resolution 20-bit charge integration ADC
- Low dark current noise < 50pA (RMS)
- Excellent ambient light range and rejection: ambient light photodiode current > 100μA, ambient light rejection > 90dB at 120Hz (Avg > 2)
- ECG (MAX86176/MAX30005):
- Clinical-grade ECG AFE with high-resolution ADC: 15.6 ENOB, 0.6μV (RMS) noise over 0.05Hz to 40Hz
- Ultra-low input bias current (−40°C to +85°C)
- Input current noise: 233fA (RMS) (0.05Hz to 40Hz, TA = +25°C)
- Fully differential input architecture with CMRR > 110dB at power line frequency
- High input impedance > 1GΩ for minimal common-mode to differential-mode conversion
- High DC offset range ±1300mV (typical 1.8V), compatible with various electrode types
- High AC dynamic range > 90mV (P-P) to prevent saturation during motion
- ECG biopotential channel applicable to select EEG applications
- Higher gain range available (480V/V, 960V/V)
- Low input-referred voltage and current noise, compatible with small dry electrodes
- System:
- Shutdown current typical value: 0.5μA
- 256-word FIFO for ECG and PPG
- True synchronous ECG and PPG data from dedicated signal paths
- Two fully configurable interrupts
- High-speed SPI or I²C interface
- Compact 2.728mm × 2.708mm WLP package
Applications
- Wearable devices for fitness, wellness, and medical applications with clinical-grade accuracy
- Suitable for wrist, finger, ear, and other body locations
- Single-lead event monitors for atrial fibrillation (A-Fib) and other arrhythmia detection
- Single-lead wireless patches for home/in-hospital monitoring
- Chest strap heart rate monitors for fitness applications
Compliance & Export Codes
| Type | Details |
|---|---|
| RoHS | |
| ECCN | EAR99 |
| CNHTS | 8542391000 |
| USHTS | |
| TARIC | |
| CAHTS | |
| BRHTS | |
| INHTS | |
| MXHTS |
| Type | Details |
|---|---|
| RoHS | |
| ECCN | EAR99 |
| CNHTS | 8542391000 |
| USHTS | |
| TARIC |
| Type | Details |
|---|---|
| CAHTS | |
| BRHTS | |
| INHTS | |