LCSC Electronics logoLCSC Electronics svg logo
Sign In
USD
ADI ADM1186-2ARQZ-REEL product image
  • ADM1186-2ARQZ-REEL thumbnail 1
  • ADM1186-2ARQZ-REEL thumbnail 2
  • ADM1186-2ARQZ-REEL thumbnail 3
  • Pinout Diagram
  • Footprint Diagram
Images for reference only

ADI ADM1186-2ARQZ-REELRoHS

Manufacturer
MPN
ADM1186-2ARQZ-REEL
LCSC Part #
C208189
Packaging
QSOP-16-150mil
Customer #
Key Attributes
Active High 4 QSOP-16-150mil Supervisors RoHS
Datasheetpdf iconADI ADM1186-2ARQZ-REEL

Products Specifications

Show similar products (0) >
TypeDescription
CategoryIntegrated Circuits (ICs)/Power Management (PMIC)/Supervisors
ManufacturerADI
PackagingQSOP-16-150mil
Reset Timeout-
Operating Temperature-40℃~+85℃@(TA)
output typeOpen-drain
Reset Active LevelActive High
ChipTypeSequence Generator
Threshold Voltage-
Number of Voltages Monitored4

Additional Information

TypeDetails
Minimum1
Multiple1
Standard Packaging2500
Sales UnitPiece

Introduction

AI Translation

The ADM1186-1 and ADM1186-2 are integrated, four-channel voltage monitoring and sequencing devices. A 2.7 V to 5.5 V power supply is required on the VCC pin for power. Four precision comparators, VIN1 to VIN4, monitor four voltage rails. All four comparators share a 0.6 V reference and have a worst-case accuracy of 0.8%. Resistor networks that are external to the VIN1, VIN2, VIN3, and VIN4 pins set the undervoltage (UV) trip points for the monitored supply rails. The ADM1186-1 and ADM1186-2 have four open-drain enable outputs, OUT1 to OUT4, that are used to enable power supplies. An open-drain power-good output, PWRGD, indicates whether the four VINx inputs are above their UV thresholds. A state machine monitors the state of the UP and DOWN pins on the ADM1186-1 or the UP/DOWN pin on the ADM1186-2 to control the supply sequencing direction. In the WAIT START state, a rising edge transition on the UP or UP/DOWN pin triggers a power-up sequence. A falling edge transition on the DOWN or UP/DOWN pin in the POWER-UP DONE state triggers a power-down sequence. During a power-up sequence, the state machine enables each power supply in turn. The supply output voltage is monitored to determine whether it rises above the UV threshold level within a user defined duration called the blanking time. If a supply rises above the UV threshold, the next enable output in the sequence is turned on. In addition to the blanking time, the user can also define a sequence time delay before each enable output is turned on. The ADM1186-1 provides an open-drain pin, SEQ_DONE, that is asserted high to provide an indication that a power-up sequence is complete. The SEQ_DONE pin allows multiple cascaded ADM1186-1 devices to perform controlled power-up and power-down sequences. During a power-down sequence, the enable outputs turn off in reverse order. The same sequence time delays used during the power-up sequence are also used during the power-down sequence as each enable output is turned off; no blanking time is used during a power-down sequence. At the end of a powerdown sequence, the SEQ_DONE pin is brought low. During sequencing and when powered up, the state machine continuously monitors the part for any fault conditions. Faults include a UV condition on any of the inputs or an unexpected control input. Any fault causes the state machine to enter a fault handler, which immediately turns off all enable outputs and then ensures that the device is ready to start a new power-up sequence. The ADM1186-1 has a bidirectional pin, FAULT, that facilitates fault handling when using multiple devices. If an ADM1186-1 experiences a fault condition, the FAULT pin is driven low, causing other connected ADM1186-1 devices to enter their own fault handling states. The ADM1186-1 is available in a 20-lead QSOP package, and the ADM1186-2 is available in a 16-lead QSOP package.

Features

AI Translation
  • Powered from 2.7 V to 5.5 V on the VCC pin
  • Monitors four supplies via 0.8% accurate comparators
  • Digital core supports up and down supply sequencing
  • Multiple devices can be cascaded (ADM1186-1)
  • Four inputs can be programmed to monitor different voltage levels with resistor dividers
  • Capacitor programmable supply sequence time delays and a timeout delay to sq0 accuracy at 25°C
  • Four open-drain enable outputs
  • Open-drain power-good output
  • Open-drain sequence complete pin and bidirectional open-drain fault pin (ADM1186-1 only)

Applications

AI Translation
  • Monitor and alarm functions
  • Up and down power supply sequencing
  • Telecommunication and data communication equipment
  • PCs, servers, and notebook PCs
Out of Stock
Stock Notification
Add to BOM List
QtyUnit Price(Reference Only)Total Amount
1+$ 10.0759$ 10.08
10+$ 9.7713$ 97.71
Standard Packaging2500/Full Reel
Better price for more quantity?
$