Astrodyne TDI ESMA-0105
| Manufacturer | |
| MPN | ESMA-0105 |
| LCSC Part # | C20179481 |
| Packaging | - |
| Customer # | |
| Key Attributes | 10W Ultraminiature Medical Encapsulated Switchers |
| Datasheet |
Products Specifications
Show similar products (0) >| Type | Description | |
|---|---|---|
| Category | Power Supplies/Power Suppliers - Board Mount/AC DC Converters | |
| Manufacturer | Astrodyne TDI | |
| Packaging | - | |
| Features | Overvoltage protection;Short Circuit Protection;Fault self-recovery |
Report an ErrorShow similar products (0) >
Additional Information
| Type | Details |
|---|---|
| Minimum | 1 |
| Multiple | 1 |
| Standard Packaging | 1 |
| Sales Unit | Piece |
| EDA Models | EasyEDA Model |
Features
AI Translation
- All measurements shall be performed directly at the output terminals.
- Ripple and noise are dependent on the output voltage specified for the particular model.
- Short-circuit protection automatically recovers once the overcurrent condition is removed.
- Isolation capability up to 1 minute.
- Suitable for free-air convection cooling.
- No minimum load required for normal operation. However, auxiliary outputs should be adjusted based on the minimum load of the main output; otherwise, load regulation will degrade.
- Load regulation measured between 20% and full load.
- Line regulation measured between 90VAC and 264VAC.
- Preset accuracy measured at nominal load with 120VAC input.
- I/O noise measured peak-to-peak directly at the pins/terminals under nominal load, with 0.1uF bypass capacitor, 20MHz bandwidth.
- Cross regulation: measured output (5V for triple-output models) with all other outputs varying between 60% and 100% load, at nominal load.
- 100% product tested.
Out of Stock
Notify Me
Add to BOM List
| Qty | Unit Price(Reference Only) | Total Amount |
|---|---|---|
| 1+ | $ 62.0763 | $ 62.08 |
| 200+ | $ 24.7696 | $ 4953.92 |
| 500+ | $ 23.9419 | $ 11970.95 |
| 1,000+ | $ 23.5327 | $ 23532.70 |
Standard Packaging1/Full Box | ||
Better price for more quantity?
$
Products Specifications
Show similar products (0) >| Type | Description | |
|---|---|---|
| Category | Power Supplies/Power Suppliers - Board Mount/AC DC Converters | |
| Manufacturer | Astrodyne TDI | |
| Packaging | - | |
| Features | Overvoltage protection;Short Circuit Protection;Fault self-recovery |
Report an ErrorShow similar products (0) >
Additional Information
| Type | Details |
|---|---|
| Minimum | 1 |
| Multiple | 1 |
| Standard Packaging | 1 |
| Sales Unit | Piece |
| EDA Models | EasyEDA Model |
Features
AI Translation
- All measurements shall be performed directly at the output terminals.
- Ripple and noise are dependent on the output voltage specified for the particular model.
- Short-circuit protection automatically recovers once the overcurrent condition is removed.
- Isolation capability up to 1 minute.
- Suitable for free-air convection cooling.
- No minimum load required for normal operation. However, auxiliary outputs should be adjusted based on the minimum load of the main output; otherwise, load regulation will degrade.
- Load regulation measured between 20% and full load.
- Line regulation measured between 90VAC and 264VAC.
- Preset accuracy measured at nominal load with 120VAC input.
- I/O noise measured peak-to-peak directly at the pins/terminals under nominal load, with 0.1uF bypass capacitor, 20MHz bandwidth.
- Cross regulation: measured output (5V for triple-output models) with all other outputs varying between 60% and 100% load, at nominal load.
- 100% product tested.
Compliance & Export Codes
| Type | Details |
|---|---|
| RoHS | |
| ECCN | - |
| CNHTS | 8504902000 |
| USHTS | 8504909690 |
| TARIC | 8504909000 |
| CAHTS | 8504909090 |
| BRHTS | 85049020 |
| INHTS | 85049090 |
| MXHTS | 8504.90.99 |
| Type | Details |
|---|---|
| RoHS | |
| ECCN | - |
| CNHTS | 8504902000 |
| USHTS | 8504909690 |
| TARIC | 8504909000 |
| Type | Details |
|---|---|
| CAHTS | 8504909090 |
| BRHTS | 85049020 |
| INHTS | 85049090 |
| MXHTS | 8504.90.99 |