Key Attributes
Enhanced Poly-Phase High-Performance Wide-Span Energy Metering IC
Datasheetpdf iconMICROCHIP ATM90E32AS-AU-R

Products Specifications

Show similar products (0) >
TypeDescription
CategoryIntegrated Circuits (ICs)/Power Management (PMIC)/Energy Metering
ManufacturerMICROCHIP
PackagingTQFP-48(7x7)
Clock Frequency16.384MHz
Tolerance0.1%
Operating Temperature-40℃~+85℃
Voltage - Supply2.8V~3.6V
Dynamic Range6000:1
FunctionBuilt-in temperature sensor;Pulse output;Built-in reference source;Energy accumulation engine;Harmonic analysis;Fault detection;Interrupt control;Digital calibration and compensation
Voltage Reference Drift6ppm/℃
Number of Channels6
InterfaceSPI
Meter TypePolyphase Energy Metering IC
Current - Supply13mA

Additional Information

TypeDetails
Minimum1
Multiple1
Standard Packaging1000
Sales UnitPiece

Introduction

AI Translation

The M90E32AS is a poly-phase high performance wide-dynamic range metering IC. The M90E32AS incorporates 6 independent 2nd order sigma-delta ADCs, which could be employed in three voltage channels (phase A, B and C) and three current channels (phase A, B, C) in a typical three-phase four-wire system. The M90E32AS has an embedded DSP which executes calculation of active energy, reactive energy, apparent energy, fundamental and harmonic active energy over ADC signal and on-chip reference voltage. The DSP also calculates measurement parameters such as voltage and current RMS value as well as mean active/reactive/apparent power. The M90E32AS is suitable for poly-phase multi-function meters which could measure active/reactive/apparent energy and fundamental/harmonic energy either through four independent energy pulse outputs CF1/CF2/CF3/CF4 or through the corresponding registers. The ADC and auto-temperature compensation technology for reference voltage ensure the M90E32AS's long-term stability over variations in grid and ambient environment conditions.

Features

AI Translation
  • Metering features fully in compliance with the requirements of IEC62052-11, IEC62053-22 and IEC62053-23, ANSI C12.1 and ANSI C12.20; applicable in polyphase class 0.2S, 0.5S or class 1 watt-hour meter or class 2 var-hour meter.
  • Accuracy of ±0.1% for active energy and ±0.2% for reactive energy over a dynamic range of 6000:1.
  • Temperature coefficient is 6 ppm/°C (typ.) for on-chip reference voltage. Automatically temperature compensated.
  • Single-point calibration on each phase over the whole dynamic range for active energy; no calibration needed for reactive/ apparent energy.
  • ±1 °C (typ.) temperature sensor accuracy.
  • Flexible piece-wise non-linearity compensation: three current (RMS value)-based segments with two programmable thresholds for each phase. Independent gain and phase angle compensation for each segment.
  • Electrical parameters measurement: less than ±0.5% fiducial error for Vrms, Irms, mean active/ reactive/ apparent power, frequency, power factor and phase angle.
  • Active (forward/reverse), reactive (forward/reverse), apparent energy with independent energy registers.
  • Programmable startup and no-load power thresholds.
  • 6 dedicated ADCs for phase A/B/C current and voltage sampling circuits. Current sampled over Current Transformer (CT) or Rogowski coil (di/dt coil); voltage sampled over resistor divider network.
  • Programmable power modes: Normal, Idle, Detection and Partial Measurement mode.
  • Fundamental (0.2%) and harmonic (1%) active energy with dedicated energy / power registers and independent energy outputs.
  • Current and voltage instantaneous signal monitoring.
  • Enhanced event detection: sag, over voltage, phase loss, over current, reverse V/I phase sequence, calculated neutral line current |NC over-current and frequency upper and lower threshold.
  • 3.3V single power supply. Operating voltage range: 2.8V~3.6V. Metering accuracy guaranteed within 3.0V~3.6V.
  • Four-wire SPI interface.
  • Programmable voltage sag detection and zero-crossing output.
  • Crystal oscillator frequency: 16.384MHz. On-chip two capacitors and no need of external capacitors.
  • Lower power consumption. =13mA (typ.) in Normal mode.
  • TQFP48 package.
  • Operating temperature: -40 °C~+85 °C.

Applications

AI Translation
  • Poly-phase energy meters of class 0.2S, 0.5S and class 1 which are used in three-phase four-wire (3P4W, Y0) or three-phase three-wire (3P3W, Y or Δ) systems.
  • Power monitoring instruments which need to measure voltage, current, mean power, etc.
In-Stock: 1,120