LCSC Electronics logoLCSC Electronics svg logo
Sign In
USD
US Electronics Inc. USW-115T product image
Images for reference only

US Electronics Inc. USW-115TRoHS

Manufacturer
MPN
USW-115T
LCSC Part #
C17484715
Packaging
Through Hole
Customer #
Key Attributes
126℃ 10A 100℃ Through Hole Thermal Cutoffs (Thermal Fuses) RoHS
Datasheetpdf iconUS Electronics Inc. USW-115T
Out of Stock
Notify Me
Add to BOM List
QtyUnit Price(Reference Only)Total Amount
1+$ 1.3769$ 1.38
200+$ 0.5499$ 109.98
500+$ 0.5317$ 265.85
1,000+$ 0.5226$ 522.60
Standard Packaging5/Full Bag
Better price for more quantity?
$

Products Specifications

Show similar products (0) >
TypeDescription
CategoryCircuit Protection/Thermal Cutoffs (Thermal Fuses)
ManufacturerUS Electronics Inc.
PackagingThrough Hole
Rated Functioning Temperature126℃
Current Rating10A
Maximum Temperature Limit-
Holding Temperature100℃

Additional Information

TypeDetails
Minimum1
Multiple1
Standard Packaging5
Sales UnitPiece

Introduction

AI Translation

USW-1 Series thermal cutoffs — most models are CUL, TUL, and UL certified under UL file number E126429, with dual ratings (UL certified): 250V 10A and 125V 15A. Rated voltage: 250VAC and 125VAC; rated current: 10A at 250VAC, 15A at 125VAC; interrupting current: 250VAC, 15A. Transient overload test current: DC current pulse, amplitude 150A, duration 3ms, interval 10s, applied continuously for 100 cycles. Parameters including rated operating temperature, holding temperature, rated current, interrupting current, transient overload current, and rated voltage are also specified.

Features

AI Translation
  • cUL, TUL, and UL certified for most models
  • Dual ratings: 250V 10A and 125V 15A
  • Voltage rating: 250VAC and 125VAC
  • Current rating: 10A at 250VAC, 15A at 125VAC
  • Breaking current: 250VAC, 15A
  • Transient overload test current: DC current pulse, amplitude 150A, duration 3ms, interval 10s, 100 cycles applied continuously