LCSC Electronics logoLCSC Electronics svg logo
Sign In
USD
RENERGY RN8302B product image
  • RN8302B thumbnail 1
  • RN8302B thumbnail 2
  • RN8302B thumbnail 3
  • Pinout
  • Footprint
Images for reference only

RENERGY RN8302BRoHS

Manufacturer
RENERGYAsian Brands
MPN
RN8302B
LCSC Part #
C84227
Packaging
LQFP-44(10x10)
Customer #
Key Attributes
Three-phase Anti-tampering Multifuction Electircal Energy Meter IC
Datasheetpdf iconRENERGY RN8302B
In-Stock: 1,858
1,858 In stock, ships now
Minimum: 1Multiple: 1Sales Unit: Piece
Add to BOM List
QtyUnit PriceTotal Amount
1+$ 2.423$ 2.42
10+$ 2.06$ 20.60
30+$ 1.831$ 54.93
160+$ 1.5067$ 241.07
480+$ 1.4019$ 672.91
960+$ 1.3551$ 1300.90
Standard Packaging160/Full Tray
Better price for more quantity?
$

Products Specifications

All
TypeDescription
CategoryIntegrated Circuits (ICs)/Power Management (PMIC)/Energy Metering
ManufacturerRENERGY
PackagingLQFP-44(10x10)
Clock Frequency8.192MHz
Tolerance0.1%
Operating Temperature-40℃~+85℃
Voltage Reference Value1.25V
Voltage - Supply3V~3.6V
Dynamic Range5000:1
FunctionProgrammable gain;Pulse output;Built-in reference source;Energy accumulation engine;Harmonic analysis;Fault detection;Anti-tamper detection;Interrupt control;Digital calibration and compensation
Number of Channels7
InterfaceSPI
Meter TypePolyphase Energy Metering IC
Current - Supply5mA

Introduction

AI Translation

The RN8302B provides full-wave and fundamental active, reactive, and apparent energy and power, supports reactive four-quadrant detection, features creep start functionality, adjustable meter constant, fast pulse counting, and pulse output. It measures full-wave and fundamental power, RMS voltage and current, power factor, line frequency, and phase angle, with zero-crossing detection, phase sequence error detection, and voltage loss indication. Anti-tamper functionality and multiple low-power modes are supported. Software calibration is supported for three-phase three-wire and three-phase four-wire configurations. Powered by a single +3.3V supply with power monitoring, built-in 1.25V ADC reference voltage, high-speed SPI interface, and interrupt output pin. Operating voltage range: 3.0V–3.6V; operating temperature range: -40℃–85℃. Available in LQFP44 green package, compliant with EU RoHS directive. The chip supports four operating modes: metering mode, total voltage loss mode 1, total voltage loss mode 2, and sleep mode. Mode switching is performed via SPI commands, and the default mode after power-on reset is configurable via the PM pin.

Features

AI Translation
  • Total-waveform and fundamental active energy measurement; nonlinearity error <0.1% over 5000:1 dynamic range; meets Class 0.5S and Class 0.2S active energy meter accuracy requirements
  • Total-waveform and fundamental reactive energy measurement; nonlinearity error <0.1% over 5000:1 dynamic range
  • Total-waveform and fundamental apparent energy measurement
  • Active and reactive power direction indication; reactive four-quadrant detection
  • Anti-creep function with adjustable startup threshold
  • Adjustable meter constant
  • Fast pulse count output for active, reactive, and apparent energy
  • Pulse output for total-waveform and fundamental active, reactive, and apparent energy
  • Total-waveform and fundamental active, reactive, and apparent power
  • Total-waveform, fundamental, and harmonic three-phase voltage/current RMS values
  • Total-waveform and fundamental power factor
  • Line frequency measurement; measurement error <0.02%
  • Per-phase voltage and current phase angle; measurement error <0.02°
  • Seven-channel zero-crossing detection with configurable threshold
  • Voltage phase sequence error detection
  • Voltage loss indication with configurable threshold
  • Flexible voltage and current waveform sample buffer
  • Voltage sag detection
  • Overvoltage and overcurrent detection
  • Neutral current measurement
  • Low-power mode NVM2 for current comparison pre-detection; 2-level configurable threshold; power consumption <150μA
  • Low-power mode NVM1 for low-power current RMS measurement; power consumption <2mA
  • Active full power-loss reporting; typical average power consumption of 7μA
  • Seven-channel ADC gain calibration
  • Seven-channel ADC phase calibration; Phase A, B, C current channels support segmented phase calibration
  • Power gain calibration
  • Segmented phase calibration for active and reactive power
  • Offset calibration for active power, reactive power, and RMS
  • Checksum register with automatic calibration data verification
  • Supports three-phase three-wire and three-phase four-wire configurations
  • Single +3.3V supply with power monitoring
  • Built-in 1.25V ADC voltage reference; typical temperature coefficient 5ppm/℃; external reference supported
  • High-speed SPI interface up to 3.5Mbps with write protection
  • One interrupt output pin
  • Operating voltage range: 3.0V – 3.6V
  • Operating temperature range: -40℃ – 85℃
  • LQFP44 green package
  • Compliant with the test requirements of EU Directive (EU) 2015/863 amending Annex II of RoHS Directive 2011/65/EU

Applications

AI Translation
  • Three-phase three-wire meter
  • Three-phase four-wire meter