YLPTEC TD322DCAN
| Manufacturer | YLPTECAsian Brands |
| MPN | TD322DCAN |
| LCSC Part # | C5451822 |
| Packaging | DIP-12 |
| Customer # | |
| Key Attributes | Universal Dual-channel and Dual-isolated CAN Transceiver |
| Datasheet |
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Interface/Modules | |
| Manufacturer | YLPTEC | |
| Packaging | DIP-12 | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage - Supply | 3.15V~3.45V | |
| Output Port | CAN Interface | |
| Features | Multi-bus bidirectional translation;Dominant timeout | |
| Isolation | With Isolation | |
| Data Rate | 1Mbps | |
| Quiescent Current | 63mA |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Interface/Modules | |
| Manufacturer | YLPTEC | |
| Packaging | DIP-12 | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage - Supply | 3.15V~3.45V |
| Type | Description | |
|---|---|---|
| Output Port | CAN Interface | |
| Features | Multi-bus bidirectional translation;Dominant timeout | |
| Isolation | With Isolation | |
| Data Rate | 1Mbps | |
| Quiescent Current | 63mA |
Introduction
The TD322DCAN/TD522DCAN general-purpose dual-channel dual-isolated CAN transceiver module series is a two-channel CAN bus transceiver module integrating an isolated power supply, signal isolation chip, and CAN transceiver chip. The primary function is to convert logic-level signals to CAN bus differential levels, achieve signal isolation, and provide mutual isolation between the two CAN bus transceivers. The module features a built-in regulated isolated power supply capable of 2500VDC electrical isolation, along with high ESD protection. It can be easily embedded into user equipment, enabling seamless CAN bus network connectivity.
Features
- Compliant with ISO 11898-2
- Unpowered nodes do not affect the bus
- Supports at least 110 nodes per network
- Housing and potting compound compliant with UL94-V0
- Ultra-low EMI emission and high EMI immunity
- Excellent high/low temperature performance, meeting industrial-grade requirements
Applications
- Automotive electronics
- Instrumentation
- Railway transportation
- Petrochemical
- Power monitoring
- Industrial control
- Smart home
- CAN bridge
- CAN repeater
- Transceiver testing
- Short-range communication testing
| Qty | Unit Price | Total Amount |
|---|---|---|
| 1+ | $ 7.1542 | $ 7.15 |
| 10+ | $ 6.1285 | $ 61.29 |
| 25+ | $ 5.5046 | $ 137.62 |
| 100+ | $ 4.979 | $ 497.90 |
Standard Packaging25/Full Tube | ||
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Interface/Modules | |
| Manufacturer | YLPTEC | |
| Packaging | DIP-12 | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage - Supply | 3.15V~3.45V | |
| Output Port | CAN Interface | |
| Features | Multi-bus bidirectional translation;Dominant timeout | |
| Isolation | With Isolation | |
| Data Rate | 1Mbps | |
| Quiescent Current | 63mA |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Interface/Modules | |
| Manufacturer | YLPTEC | |
| Packaging | DIP-12 | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage - Supply | 3.15V~3.45V |
| Type | Description | |
|---|---|---|
| Output Port | CAN Interface | |
| Features | Multi-bus bidirectional translation;Dominant timeout | |
| Isolation | With Isolation | |
| Data Rate | 1Mbps | |
| Quiescent Current | 63mA |
Introduction
The TD322DCAN/TD522DCAN general-purpose dual-channel dual-isolated CAN transceiver module series is a two-channel CAN bus transceiver module integrating an isolated power supply, signal isolation chip, and CAN transceiver chip. The primary function is to convert logic-level signals to CAN bus differential levels, achieve signal isolation, and provide mutual isolation between the two CAN bus transceivers. The module features a built-in regulated isolated power supply capable of 2500VDC electrical isolation, along with high ESD protection. It can be easily embedded into user equipment, enabling seamless CAN bus network connectivity.
Features
- Compliant with ISO 11898-2
- Unpowered nodes do not affect the bus
- Supports at least 110 nodes per network
- Housing and potting compound compliant with UL94-V0
- Ultra-low EMI emission and high EMI immunity
- Excellent high/low temperature performance, meeting industrial-grade requirements
Applications
- Automotive electronics
- Instrumentation
- Railway transportation
- Petrochemical
- Power monitoring
- Industrial control
- Smart home
- CAN bridge
- CAN repeater
- Transceiver testing
- Short-range communication testing
C5451822 EasyEDA Library
Compliance & Export Codes
| Type | Details |
|---|---|
| RoHS | |
| ECCN | - |
| CNHTS | 8538900000 |
| USHTS | 8538901000 |
| TARIC | 8538901900 |
| CAHTS | 8538909090 |
| BRHTS | 85389090 |
| INHTS | 85389000 |
| MXHTS | 8538.90.01 |
| Type | Details |
|---|---|
| RoHS | |
| ECCN | - |
| CNHTS | 8538900000 |
| USHTS | 8538901000 |
| TARIC | 8538901900 |
| Type | Details |
|---|---|
| CAHTS | 8538909090 |
| BRHTS | 85389090 |
| INHTS | 85389000 |
| MXHTS | 8538.90.01 |