LM25056 System Power Measurement IC with PMBus
DatasheetTI LM25056PSQ/NOPB
RoHS Compliance1 documents available
Every Order Guarantee
100% Authentic · 30-Day Return or Replacement

Products Specifications

All
TypeDescription
CategoryIntegrated Circuits (ICs)/Power Management (PMIC)/Energy Metering
ManufacturerTI
PackagingWQFN-24(4x5)
Operating Temperature-40℃~+125℃
Voltage - Supply3V~17V
FunctionProgrammable gain;Fault detection;Built-in temperature sensor;Built-in reference source
InterfaceI2C
Current - Supply1.7mA

Introduction

AI Translation

The LM25056 combines high performance analog and digital technology with a PMBus compliant SMBus/I²C interface to accurately measure the operating conditions of electrical systems including computing and storage blades connected to a backplane power bus. The LM25056 continuously supplies real-time power, voltage, current, and temperature data to the system management host via the SMBus interface. The LM25056 monitoring block captures both realtime and average values of subsystem operating parameters (V₁ₙ, I₁ₙ, P₁ₙ, Vₐᵤₓ) as well as peak power. Accurate power measurement is accomplished by measuring the product of the input voltage and current through a shunt resistor. LM25056 current measurement has a ±1.5% accuracy over the temperature range of -40℃ to +85℃ with operation from -40℃ to +125℃. A black box (Telemetry/Fault Snapshot) function captures and stores telemetry data and device status in the event of a warning or a fault.

Features

AI Translation
  • Input Voltage Range: 3V to 17V
  • I2C/SMBus Interface with PMBus Compliant Command Structure
  • Remote Temperature Sensing with Programmable Warning and Shutdown Thresholds
  • Real Time Monitoring of VIN, IIN, PIN, VAUX with 12-bit Resolution and 1 kHz Sampling Rate
  • True Input Power Measurement Using Simultaneous Sampling of VIN and IIN
  • Accurately Averages Dynamic Power Readings
  • Averaging of V₁ₙ, I₁ₙ, P₁ₙ, and VAUX Over Programmable Interval Ranging from 0.001 to 4 Seconds
  • User Programmable WARN and FAULT Thresholds with SMBA Notification
  • Black Box Capture of Telemetry Measurements and Device Status Triggered by WARN and FAULT Conditions
  • Full Featured Application Development Software
  • WQFN-24 Package

Applications

AI Translation
  • Server Backplane Systems
  • Base Station Power Distribution Systems
  • Subsystem Power Measurement