Cirrus Logic CS5467-ISZR
| Manufacturer | |
| MPN | CS5467-ISZR |
| LCSC Part # | C3681579 |
| Packaging | SSOP-28 |
| Customer # | |
| Key Attributes | 4.75V~5.25V SPI 3.5mA SSOP-28 Energy Metering RoHS |
| Datasheet | Cirrus Logic CS5467-ISZR |
| RoHS Compliance | 2 documents available |
| Alternative Parts | 2 |
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/Energy Metering | |
| Manufacturer | Cirrus Logic | |
| Packaging | SSOP-28 | |
| Tolerance | 0.1% | |
| Clock Frequency | 4.096MHz | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage Reference Value | 2.5V | |
| Voltage - Supply | 4.75V~5.25V | |
| Dynamic Range | 1000:1 | |
| Number of Channels | 2 | |
| Function | Programmable gain;Pulse output;Built-in reference source;Fault detection;Digital calibration and compensation;Built-in temperature sensor | |
| Interface | SPI | |
| Current - Supply | 3.5mA | |
| Meter Type | Single-Phase Energy Metering IC |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/Energy Metering | |
| Manufacturer | Cirrus Logic | |
| Packaging | SSOP-28 | |
| Tolerance | 0.1% | |
| Clock Frequency | 4.096MHz | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage Reference Value | 2.5V |
| Type | Description | |
|---|---|---|
| Voltage - Supply | 4.75V~5.25V | |
| Dynamic Range | 1000:1 | |
| Number of Channels | 2 | |
| Function | Programmable gain;Pulse output;Built-in reference source;Fault detection;Digital calibration and compensation;Built-in temperature sensor | |
| Interface | SPI | |
| Current - Supply | 3.5mA | |
| Meter Type | Single-Phase Energy Metering IC |
Introduction
The CS5467 is a single-chip energy meter. It measures line voltage and current, and calculates active power, reactive power, apparent power, energy, power factor, and RMS voltage and current. If voltage measurement is disabled due to tampering, an internal RMS voltage reference can be used. Four ΔΣ ADCs are used to measure two voltages and two currents. Optionally, the voltage channel 2 can be used for temperature measurement. The CS5467 is designed to interface with a variety of voltage and current sensors. Additional features include system-level calibration, voltage sag and current fault detection, peak detection, phase compensation, and energy pulse output.
Features
- Energy linearity: ±0.1% of reading over 1000:1 dynamic range
- On-chip functions:
- Voltage and current measurement
- Active, reactive, and apparent power/energy
- RMS voltage and current calculation
- Current fault and voltage sag detection
- Calibration
- Phase compensation
- Temperature sensor
- Energy pulse output
- Accuracy specifications compliant with IEC, ANSI, and JIS
- Low power consumption
- Voltage tamper correction
- Single-supply ground-referenced input
- On-chip 2.5V reference (typical 40 ppm/°C)
- Power supply monitoring
- 3-wire serial interface to MCU or E²PROM
- Power supply configuration: GND: 0V, VA+: +5V, VD+: +3.3V ~ +5V
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/Energy Metering | |
| Manufacturer | Cirrus Logic | |
| Packaging | SSOP-28 | |
| Tolerance | 0.1% | |
| Clock Frequency | 4.096MHz | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage Reference Value | 2.5V | |
| Voltage - Supply | 4.75V~5.25V | |
| Dynamic Range | 1000:1 | |
| Number of Channels | 2 | |
| Function | Programmable gain;Pulse output;Built-in reference source;Fault detection;Digital calibration and compensation;Built-in temperature sensor | |
| Interface | SPI | |
| Current - Supply | 3.5mA | |
| Meter Type | Single-Phase Energy Metering IC |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/Energy Metering | |
| Manufacturer | Cirrus Logic | |
| Packaging | SSOP-28 | |
| Tolerance | 0.1% | |
| Clock Frequency | 4.096MHz | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage Reference Value | 2.5V |
| Type | Description | |
|---|---|---|
| Voltage - Supply | 4.75V~5.25V | |
| Dynamic Range | 1000:1 | |
| Number of Channels | 2 | |
| Function | Programmable gain;Pulse output;Built-in reference source;Fault detection;Digital calibration and compensation;Built-in temperature sensor | |
| Interface | SPI | |
| Current - Supply | 3.5mA | |
| Meter Type | Single-Phase Energy Metering IC |
Introduction
The CS5467 is a single-chip energy meter. It measures line voltage and current, and calculates active power, reactive power, apparent power, energy, power factor, and RMS voltage and current. If voltage measurement is disabled due to tampering, an internal RMS voltage reference can be used. Four ΔΣ ADCs are used to measure two voltages and two currents. Optionally, the voltage channel 2 can be used for temperature measurement. The CS5467 is designed to interface with a variety of voltage and current sensors. Additional features include system-level calibration, voltage sag and current fault detection, peak detection, phase compensation, and energy pulse output.
Features
- Energy linearity: ±0.1% of reading over 1000:1 dynamic range
- On-chip functions:
- Voltage and current measurement
- Active, reactive, and apparent power/energy
- RMS voltage and current calculation
- Current fault and voltage sag detection
- Calibration
- Phase compensation
- Temperature sensor
- Energy pulse output
- Accuracy specifications compliant with IEC, ANSI, and JIS
- Low power consumption
- Voltage tamper correction
- Single-supply ground-referenced input
- On-chip 2.5V reference (typical 40 ppm/°C)
- Power supply monitoring
- 3-wire serial interface to MCU or E²PROM
- Power supply configuration: GND: 0V, VA+: +5V, VD+: +3.3V ~ +5V
C3681579 EasyEDA Library
Compliance & Export Codes
| Type | Details |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | EAR99 |
| CNHTS | 8542399000 |
| USHTS | 8542390001 |
| TARIC | 8542399000 |
| CAHTS | 8542390000 |
| BRHTS | 85423999 |
| INHTS | 85423900 |
| MXHTS | 8542.39.99 |
| Type | Details |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | EAR99 |
| CNHTS | 8542399000 |
| USHTS | 8542390001 |
| TARIC | 8542399000 |
| Type | Details |
|---|---|
| CAHTS | 8542390000 |
| BRHTS | 85423999 |
| INHTS | 85423900 |
| MXHTS | 8542.39.99 |