Infineon ICE2A165IN
| Manufacturer | |
| MPN | ICE2A165IN |
| LCSC Part # | C3094580 |
| Packaging | DIP-8 |
| Customer # | |
| Key Attributes | 100kHz 31W 650V 6.5V~21V Flyback DIP-8 AC DC Converters, Offline Switchers RoHS |
| Datasheet | Infineon ICE2A165IN |
| RoHS Compliance | 1 documents available |
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/AC DC Converters, Offline Switchers | |
| Manufacturer | Infineon | |
| Packaging | DIP-8 | |
| Operating Temperature | -40℃~+150℃ | |
| Frequency - Switching | 100kHz | |
| Pd - Power Dissipation | 31W | |
| Voltage - Breakdown | 650V | |
| Voltage - Supply | 6.5V~21V | |
| Features | Under-voltage lockout;Adjustable soft-start;Light load efficient mode;Leading edge blanking;Adjustable current limiting;Audio noise elimination;Over Current Protection;Overtemperature protection (OTP);Over Voltage Protection | |
| Topology | Flyback | |
| Duty Cycle(Max) | 72% |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/AC DC Converters, Offline Switchers | |
| Manufacturer | Infineon | |
| Packaging | DIP-8 | |
| Operating Temperature | -40℃~+150℃ | |
| Frequency - Switching | 100kHz | |
| Pd - Power Dissipation | 31W |
| Type | Description | |
|---|---|---|
| Voltage - Breakdown | 650V | |
| Voltage - Supply | 6.5V~21V | |
| Features | Under-voltage lockout;Adjustable soft-start;Light load efficient mode;Leading edge blanking;Adjustable current limiting;Audio noise elimination;Over Current Protection;Overtemperature protection (OTP);Over Voltage Protection | |
| Topology | Flyback | |
| Duty Cycle(Max) | 72% |
Introduction
The second generation CoolSET™-F2 provides several special enhancements to satisfy the needs for low power standby and protection features. In standby mode frequency reduction is used to lower the power consumption and support a stable output voltage in this mode. The frequency reduction is limited to 20kHz/21.5 kHz to avoid audible noise. In case of failure modes like open loop, overvoltage or overload due to short circuit the device switches in Auto Restart Mode which is controlled by the internal protection unit. By means of the internal precise peak current limitation, the dimension of the transformer and the secondary diode can be sized lower which leads to more cost effective for the overall system.
Features
- 650V/800V avalanche rugged CoolMOS™
- Only few external components required
- Input Vcc Undervoltage Lockout
- 67kHz/100kHz switching frequency
- Max duty cycle 72%
- Low Power Standby Mode to meet European Commission Requirements
- Thermal Shut Down with Auto Restart
- Overload and Open Loop Protection
- Overvoltage Protection during Auto Restart
- Adjustable Peak Current Limitation via external resistor
- Overall tolerance of Current Limiting <±5%
- Internal Leading Edge Blanking
- User defined Soft Start
- Soft driving for low EMI
| Qty | Unit Price(Reference Only) | Total Amount |
|---|---|---|
| 1+ | $ 2.6432 | $ 2.64 |
| 200+ | $ 1.023 | $ 204.60 |
| 500+ | $ 0.9876 | $ 493.80 |
| 1,000+ | $ 0.969 | $ 969.00 |
Standard Packaging50/Full Bag | ||
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/AC DC Converters, Offline Switchers | |
| Manufacturer | Infineon | |
| Packaging | DIP-8 | |
| Operating Temperature | -40℃~+150℃ | |
| Frequency - Switching | 100kHz | |
| Pd - Power Dissipation | 31W | |
| Voltage - Breakdown | 650V | |
| Voltage - Supply | 6.5V~21V | |
| Features | Under-voltage lockout;Adjustable soft-start;Light load efficient mode;Leading edge blanking;Adjustable current limiting;Audio noise elimination;Over Current Protection;Overtemperature protection (OTP);Over Voltage Protection | |
| Topology | Flyback | |
| Duty Cycle(Max) | 72% |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/AC DC Converters, Offline Switchers | |
| Manufacturer | Infineon | |
| Packaging | DIP-8 | |
| Operating Temperature | -40℃~+150℃ | |
| Frequency - Switching | 100kHz | |
| Pd - Power Dissipation | 31W |
| Type | Description | |
|---|---|---|
| Voltage - Breakdown | 650V | |
| Voltage - Supply | 6.5V~21V | |
| Features | Under-voltage lockout;Adjustable soft-start;Light load efficient mode;Leading edge blanking;Adjustable current limiting;Audio noise elimination;Over Current Protection;Overtemperature protection (OTP);Over Voltage Protection | |
| Topology | Flyback | |
| Duty Cycle(Max) | 72% |
Introduction
The second generation CoolSET™-F2 provides several special enhancements to satisfy the needs for low power standby and protection features. In standby mode frequency reduction is used to lower the power consumption and support a stable output voltage in this mode. The frequency reduction is limited to 20kHz/21.5 kHz to avoid audible noise. In case of failure modes like open loop, overvoltage or overload due to short circuit the device switches in Auto Restart Mode which is controlled by the internal protection unit. By means of the internal precise peak current limitation, the dimension of the transformer and the secondary diode can be sized lower which leads to more cost effective for the overall system.
Features
- 650V/800V avalanche rugged CoolMOS™
- Only few external components required
- Input Vcc Undervoltage Lockout
- 67kHz/100kHz switching frequency
- Max duty cycle 72%
- Low Power Standby Mode to meet European Commission Requirements
- Thermal Shut Down with Auto Restart
- Overload and Open Loop Protection
- Overvoltage Protection during Auto Restart
- Adjustable Peak Current Limitation via external resistor
- Overall tolerance of Current Limiting <±5%
- Internal Leading Edge Blanking
- User defined Soft Start
- Soft driving for low EMI
C3094580 EasyEDA Library
Compliance & Export Codes
| Type | Details |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | EAR99 |
| CNHTS | 8542399000 |
| USHTS | 8542390001 |
| TARIC | 8542399000 |
| CAHTS | 8542390000 |
| BRHTS | 85423999 |
| INHTS | 85423900 |
| MXHTS | 8542.39.99 |
| Type | Details |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | EAR99 |
| CNHTS | 8542399000 |
| USHTS | 8542390001 |
| TARIC | 8542399000 |
| Type | Details |
|---|---|
| CAHTS | 8542390000 |
| BRHTS | 85423999 |
| INHTS | 85423900 |
| MXHTS | 8542.39.99 |