HUIKE HK19F-DC5V-SHG(Y)

Producent
HUIKEAsian Brands
Nr części prod.
HK19F-DC5V-SHG(Y)
Nr LCSC
C54512
Opak.
DIP,20.2x10mm
Numer Klienta
Klucz. cechy
RELAY POWER DPDT-CO 5V
Karta KatalogowaHUIKE HK19F-DC5V-SHG(Y)
Na stanie: 1,745
1,745 W magazynie, wysyłka natychmiastowa
Minimum: 1Wielokrotność: 1Jednostka sprzedaży: Piece
Dodaj do Listy BOM
Szt.Cena jedn.Suma całkowita
1+$ 0.6441$ 0.64
10+$ 0.513$ 5.13
25+$ 0.4491$ 11.23
100+$ 0.3835$ 38.35
500+$ 0.3442$ 172.10
1,000+$ 0.3245$ 324.50
Standardowa Obudowa25/Full Tube
Lepsza cena za większą ilość?
$

Specyfikacje Produktu

Wszystko
TypOpis
KategoriaRelays/Power Relays, Over 2 Amps
ProducentHUIKE
Opak.DIP,20.2x10mm
Coil Voltage5V
Switching Voltage(Max)125V@AC;30V@DC
Coil Resistance45Ω
Release Time4ms
Operate Time6ms
Length20.2mm
Height-
Contact Resistance100mΩ
Number of Pins-
Coil Type-
Width10mm
Operating Temperature-25℃~+70℃
Switching Current(Max)1A;2A
Coil Rated Power200mW
Contact Rating1A@125VAC;2A@30VDC
Contact Material-
Contact Form2 Form C: 2C (DPDT-CO)

Funkcje

Tłumaczenie AI
  • Safety Certification: C-UL TUV
  • Contact Gap: 0.15mm minimum
  • Contact Resistance: Initial value max 100mΩ; carry current 1A, open-circuit test voltage: 6VDC; measured by voltage drop method
  • Contact Rating: 125VAC CosΦ = 1, rated current 1A; 30VDC, rated current 2A
  • Coil Ratings (20℃): 3VDC, 5VDC, 6VDC, 9VDC, 12VDC, 24VDC
  • Rated Power Consumption: (±10%), 0.15W/0.2W/0.36W
  • Coil Resistance: (Ω±10%), 60/45/25, 167/125/70, 240/180/100, 540/400/220, 960/720/400, 3840/2880/1600
  • Must Operate Voltage: ≤(The voltage at which contacts operate when voltage is gradually applied to the relay, 80% of rated voltage) VDC
  • Must Release Voltage: ≥(The voltage at which contacts release when rated voltage is gradually decreased, 10% of rated voltage) VDC
  • Maximum Allowable Voltage: (130% of rated voltage) VDC
  • Operate Time: Max 6 milliseconds at rated voltage applied
  • Release Time: Max 4 milliseconds at rated voltage suddenly removed
  • Coil Temperature Rise: With maximum allowable voltage applied to coil under no-load condition, the stabilized temperature rise shall not exceed 40℃ (ambient temperature excluded)
  • Service Life:
    • Electrical Life: 1A/125VAC CosΦ = 1, min 100,000 operations at rated voltage; 2A/30VDC, min 100,000 operations at rated voltage
    • Mechanical Life: Min 10,000,000 operations under no-load condition
    • Maximum Operating Frequency: Electrical: 30 operations/min; Mechanical: 300 operations/min
  • Dielectric Strength:
    • Between contacts: 550VAC, 50/60 Hz, leakage current less than 1mA, for 1 minute
    • Between coil and contacts: 1,000VAC, 50/60 Hz, leakage current less than 1mA, for 1 minute
  • Insulation Resistance: ≥100 MΩ at 500VDC applied
  • Vibration Test:
    • Vibration I (Durability): De-energized state, double amplitude 1.5mm, frequency swept from 10Hz~55Hz~10Hz within 1 minute. Applied in X, Y, Z directions for 2 hours each, 6 hours total. No abnormality in appearance/construction and electrical function shall meet specification requirements after test
    • Vibration II (Functional): Energized state, double amplitude 1.5mm, frequency swept from 10Hz~55Hz~10Hz within 1 minute. Applied in X, Y, Z directions for 5 minutes each. No malfunction permitted during test (contact open time shall not exceed 1ms). No abnormality in appearance/construction and electrical function shall meet specification requirements after test
  • Shock Test:
    • Shock I (Durability): Peak acceleration 1000m/s², coil de-energized, 5 consecutive shocks applied in each of 3 mutually perpendicular axes. No abnormality in appearance/construction and electrical function shall meet specification requirements after test
    • Shock II (Functional): Peak acceleration 100m/s², coil energized, 2 consecutive shocks applied in each of 3 mutually perpendicular axes. No malfunction permitted during test (contact open time shall not exceed 1ms). No abnormality in appearance/construction and electrical function shall meet specification requirements after test
  • Temperature Range:
    • Operating Temperature Range: Related content not fully provided in document