LCSC Electronics logoLCSC Electronics svg logo
Anmelden
USD
ST LM335ADT product image
  • LM335ADT thumbnail 1
  • LM335ADT thumbnail 2
  • LM335ADT thumbnail 3
  • Pinbelegung
  • Footprint
Abbildung ähnlich

ST LM335ADT

Hersteller
Herst.-Teilenr.
LM335ADT
LCSC-Nr.
C361027
Verp.
SOIC-8
Kundennummer
Hauptmerkm.
Precision temperature sensors
DatenblattST LM335ADT
RoHS-Konformität3 Dokumente verfügbar
Vorrätig: 66
66 Ab Lager, sofort versandfertig
Minimum: 1Vielfaches: 1Verkaufseinheit: Piece
Zur BOM-Liste hinzufügen
Stk.E-PreisGesamtbetrag
1+$ 1.7057$ 1.71
10+$ 1.4502$ 14.50
30+$ 1.2907$ 38.72
100+$ 1.1279$ 112.79
500+$ 1.0547$ 527.35
1,000+$ 1.0221$ 1022.10
2,500+$ 1.0091$ 2522.75
5,000+$ 1.001$ 5005.00
Standardgehäuse2500/Full Reel
Besserer Preis bei größerer Menge?
$

Produktspezifikationen

Alle
TypBeschreibung
KategorieSensors, Transducers/Temperature Sensors/Analog and Digital Output
HerstellerST
Verp.SOIC-8
Operating Temperature-40℃~+100℃
Detection Temperature Range-40℃~+100℃
Voltage - Supply-
Interface-
Tolerance±1℃
Standby Current-
Temperature Conversion Time-
FeaturesFactory temperature calibration
Temperature Resolution-

Beschreibung

KI-Übersetzung

The LM135,LM235,LM335 are precision temperature sensors which can be easily calibrated. They operate as a 2-terminal Zener and the breakdown voltage is directly proportional to the absolute temperature at 10mV / °K. The circuit has a dynamic impedance of less than 1Ω and operates within a range of current from 450μA to 5mA without alteration of its characteristics. Calibrated at +25°C, the LM135,LM235,and LM335 have a typical error of less than 1°C over a 100°C temperature range. Unlike other sensors, the LM135,LM235,LM335 have a linear output.

Merkmale

KI-Übersetzung
  • Directly calibrated in °K
  • 1°C initial accuracy
  • Operates from 450μA to 5mA
  • Less than 1Ω dynamic impedance

Anwendungen

KI-Übersetzung
  • Accuracy improvable via single-point calibration
  • Self-heating must be considered; operate at low current sufficient to drive the sensor and calibration circuit up to maximum operating temperature
  • If ambient thermal resistance is constant, self-heating error can be corrected through external calibration (using temperature-stable current bias)
  • Suitable for basic temperature sensing, calibrated sensor applications, average temperature sensing, isolated temperature sensing, simple temperature controllers, Celsius thermometers, differential temperature sensing, thermocouple cold-junction compensation, and more