LCSC Electronics logoLCSC Electronics svg logo
Accedi
USD
LSI/CSI LS7634FO product image
Immagini a scopo illustrativo

LSI/CSI LS7634FO

Produttore
Cod. Prod.
LS7634FO
Cod. LCSC
C3229723
Imballo
DIP-8
Numero Cliente
Attr. chiave
DIP-8 Lighting, Ballast Controllers RoHS
Scheda TecnicaLSI/CSI LS7634FO
Garanzia su ogni ordine
100% Autentico · Reso o Sostituzione entro 30 Giorni
Esaurito
Avvisami
Minimo: 1Multiplo: 1Unità di vendita: Piece
Aggiungi alla Lista BOM
QtàPr. unit.(Solo per riferimento)Importo totale
1+$ 1.1712$ 1.17
200+$ 0.4537$ 90.74
500+$ 0.4383$ 219.15
1,000+$ 0.4305$ 430.50
Package Standard50/Full Tube
Prezzo migliore per quantità maggiore?
$

Specifiche del Prodotto

Tutto
TipoDescrizione
CategoriaIntegrated Circuits (ICs)/Power Management (PMIC)/Lighting, Ballast Controllers
ProduttoreLSI/CSI
ImballoDIP-8
FeaturesDimming function;Touch control function;Built-in soft-start
Frequency - Switching-
Driver Type-
Operating temperature0℃~+90℃
Input Voltage4.5V~5.5V
Output Voltage-
Output Current35mA

Descrizione

Traduzione AI

A typical electronic dimmer may not operate properly with the inductive load encountered when driving a transformer-coupled low-voltage halogen lamp. The inductive load can cause a phenomenon called half-waving, wherein the triac fires in alternate half-cycles only, which may lead to the thermal destruction of the load transformer. The problems encountered in driving an inductive load are addressed by the LS7634/LS7635 family of CMOS ICs as follows:

  1. Delayed triac cut-off. When a trigger pulse is due to occur at a conduction angle which coincides with the on-state of the triac, the trigger pulse is delayed until the triac has turned off. This eliminates the underlying cause of half-waving.
  2. Delayed triac turn-on and safety shutdown With inductive loads, the holding current needed to maintain the triac On-State, may seriously lag behind the gate trigger signal causing the triac to turn off prematurely. If the frequency of occurrences of the delayed turn-on exceeds a preset threshold, a shutdown is initiated by turning off the triac trigger pulses. The safety-shutdown threshold value is accumulated in a 4-bit Up/Down counter. The count increments for every occurrence of delayed turn-on and decrements once every 8 SYNC pulses (AC line cycles). The counter will not decrement below zero. If the count reaches 15, the safety-shut-down is effected.

Caratteristiche

Traduzione AI
  • Touch or pushbutton control of high-voltage lamps and transformer-coupled low-voltage halogen lamps (Magnetic Transformers and most Electronic Transformers)
  • Automatic Safety Shutdown
  • Three operating modes
  • Extension input for remote activation
  • 50Hz/60Hz AC line frequency
  • +5V Power Supply (VDD - VSS)

Applicazioni

Traduzione AI
  • Electronic dimmers for wall switch control of ceiling mounted lighting
  • Foot switch control of large floor lamps
  • Hand switch control of table lamps