ATLAS ENV-40-EC-K1.0
| Fabricant | |
| Réf. Fab. | ENV-40-EC-K1.0 |
| Réf. LCSC | C17528482 |
| Condit. | - |
| Numéro Client | |
| Caract. clés | +1℃~+110℃ Test and Measurement Accessories RoHS |
| Fiche Technique | ATLAS ENV-40-EC-K1.0 |
Spécifications du Produit
| Type | Description | |
|---|---|---|
| Catégorie | Measuring & Inspecting/Inspecting/Test and Measurement Accessories | |
| Fabricant | ATLAS | |
| Condit. | - | |
| Detection Temperature Range | +1℃~+110℃ | |
| Voltage - Supply | - | |
| Interface | - | |
| Tolerance | - | |
| Standby Current | - | |
| Operating Temperature | - | |
| Features | - | |
| Temperature Conversion Time | - | |
| Temperature Resolution | - |
| Type | Description | |
|---|---|---|
| Catégorie | Measuring & Inspecting/Inspecting/Test and Measurement Accessories | |
| Fabricant | ATLAS | |
| Condit. | - | |
| Detection Temperature Range | +1℃~+110℃ | |
| Voltage - Supply | - | |
| Interface | - |
| Type | Description | |
|---|---|---|
| Tolerance | - | |
| Standby Current | - | |
| Operating Temperature | - | |
| Features | - | |
| Temperature Conversion Time | - | |
| Temperature Resolution | - |
Description
This conductivity probe features a graphite construction with a conductivity measurement range of 5 - 200,000 μS/cm, accuracy of ±2%, response time of 90% within 1 second, temperature range of 1 - 110 °C, maximum pressure of 3447 kPa (500 PSI), maximum depth of 352 m (1157 ft), connector options of male SMA/male BNC (optional), cable length of 1 meter, no internal temperature sensor required, time before recalibration of approximately 10 years, expected service life of approximately 10 years, weight of 43 grams, graphite measurement surface, dimensions of 12 mm x 145.5 mm (0.47 in x 5.7 in), male SMA connector, chemical sterilization only, and food safety compliant.
Caractéristiques
- Conductivity measurement range: 5 - 200,000 μS/cm
- Accuracy: ±2%
- Response time: 90% within 1 second
- Temperature range: 1 - 110 °C
- Maximum pressure: 3447 kPa (500 PSI)
- Maximum depth: 352 m (1157 ft)
- Cable length: 1 m
- Time before recalibration: ~10 years
- Expected lifespan: ~10 years
- Weight: 43 g
- Measurement surface: Graphite
- Dimensions: 12 mm x 145.5 mm (0.47 in x 5.7 in)
- SMA connector: Male
- Sterilization method: Chemical sterilization only
- Food safe: Yes
Applications
Standard laboratory use, field use, aquariums, hydroponics, aquaculture
Spécifications du Produit
| Type | Description | |
|---|---|---|
| Catégorie | Measuring & Inspecting/Inspecting/Test and Measurement Accessories | |
| Fabricant | ATLAS | |
| Condit. | - | |
| Detection Temperature Range | +1℃~+110℃ | |
| Voltage - Supply | - | |
| Interface | - | |
| Tolerance | - | |
| Standby Current | - | |
| Operating Temperature | - | |
| Features | - | |
| Temperature Conversion Time | - | |
| Temperature Resolution | - |
| Type | Description | |
|---|---|---|
| Catégorie | Measuring & Inspecting/Inspecting/Test and Measurement Accessories | |
| Fabricant | ATLAS | |
| Condit. | - | |
| Detection Temperature Range | +1℃~+110℃ | |
| Voltage - Supply | - | |
| Interface | - |
| Type | Description | |
|---|---|---|
| Tolerance | - | |
| Standby Current | - | |
| Operating Temperature | - | |
| Features | - | |
| Temperature Conversion Time | - | |
| Temperature Resolution | - |
Description
This conductivity probe features a graphite construction with a conductivity measurement range of 5 - 200,000 μS/cm, accuracy of ±2%, response time of 90% within 1 second, temperature range of 1 - 110 °C, maximum pressure of 3447 kPa (500 PSI), maximum depth of 352 m (1157 ft), connector options of male SMA/male BNC (optional), cable length of 1 meter, no internal temperature sensor required, time before recalibration of approximately 10 years, expected service life of approximately 10 years, weight of 43 grams, graphite measurement surface, dimensions of 12 mm x 145.5 mm (0.47 in x 5.7 in), male SMA connector, chemical sterilization only, and food safety compliant.
Caractéristiques
- Conductivity measurement range: 5 - 200,000 μS/cm
- Accuracy: ±2%
- Response time: 90% within 1 second
- Temperature range: 1 - 110 °C
- Maximum pressure: 3447 kPa (500 PSI)
- Maximum depth: 352 m (1157 ft)
- Cable length: 1 m
- Time before recalibration: ~10 years
- Expected lifespan: ~10 years
- Weight: 43 g
- Measurement surface: Graphite
- Dimensions: 12 mm x 145.5 mm (0.47 in x 5.7 in)
- SMA connector: Male
- Sterilization method: Chemical sterilization only
- Food safe: Yes
Applications
Standard laboratory use, field use, aquariums, hydroponics, aquaculture
Conformité & Codes d'Exportation
| Type | Détails |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | EAR99 |
| CNHTS | 9025191010 |
| USHTS | 9025194000 |
| TARIC | 9025190010 |
| CAHTS | 9025190011 |
| BRHTS | 90251910 |
| INHTS | 90251910 |
| MXHTS | 9025.19.01 |
| Type | Détails |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | EAR99 |
| CNHTS | 9025191010 |
| USHTS | 9025194000 |
| TARIC | 9025190010 |
| Type | Détails |
|---|---|
| CAHTS | 9025190011 |
| BRHTS | 90251910 |
| INHTS | 90251910 |
| MXHTS | 9025.19.01 |

