MAXIM MAX32664GTGA+
| 製造商 | |
| 製造商料號 | MAX32664GTGA+ |
| LCSC 編號 | C17351452 |
| 包裝 | TQFN-24(3x3) |
| 客戶編號 | |
| 關鍵特性 | I2C TQFN-24(3x3) Sensor and Detector Interfaces RoHS |
| 數據手冊 | MAXIM MAX32664GTGA+ |
| RoHS 合規 | 1 份文件可用 |
產品規格
| 類型 | 描述 | |
|---|---|---|
| 類別 | Integrated Circuits (ICs)/Interface/Sensor and Detector Interfaces | |
| 製造商 | MAXIM | |
| 包裝 | TQFN-24(3x3) | |
| Operating Temperature | -40℃~+105℃ | |
| Voltage - Supply | 1.71V~3.63V | |
| Interface | I2C | |
| Length | 3mm | |
| Width | 3mm | |
| Height | 0.75mm |
| 類型 | 描述 | |
|---|---|---|
| 類別 | Integrated Circuits (ICs)/Interface/Sensor and Detector Interfaces | |
| 製造商 | MAXIM | |
| 包裝 | TQFN-24(3x3) | |
| Operating Temperature | -40℃~+105℃ | |
| Voltage - Supply | 1.71V~3.63V |
| 類型 | 描述 | |
|---|---|---|
| Interface | I2C | |
| Length | 3mm | |
| Width | 3mm | |
| Height | 0.75mm |
概述
The MAX32664 is a sensor hub family with embedded firmware and world-class algorithms for wearables. It seamlessly enables customer-desired sensor functionality, including communication with Analog Devices' optical sensor solutions and delivering raw or calculated data to the outside world. This is achieved while keeping overall system power consumption in check. The device family interfaces to a microcontroller host through a fast-mode slave I2C interface for access to raw and processed sensor data as well as field updates. A firmware bootloader is also provided.
The MAX32664 Version A supports the MAX30101/ MAX30102 high-sensitivity pulse oximeter and heart-rate sensor for wearable health for finger-based applications. A master mode I2C interface for communication with sensors is provided.
The MAX32664 Version B supports the MAX86140/ MAX86141 for wrist-based applications. A master mode SPI interface for communication with sensors is provided.
The MAX32664 Version C supports the MAX86140/ MAX86141 for wrist-based applications and MAXM86161 for ear-based applications. The device provides either a master mode SPI or an I2C interface for communication with sensors.
The MAX32664 Version D supports the MAX30101/ MAX30102 high-sensitivity pulse oximeter and heart-rate sensor for wearable health for finger-based applications. A master mode I2C interface for communication with sensors is provided. Version D also supports estimated blood pressure monitoring.
The wearable algorithms in the MAX32664 sensor hub support a directly connected accelerometer. They also allow feeding of X, Y, and Z samples from a host-connected accelerometer. This architecture provides robust detection and compensation of motion artifacts in captured samples.
The tiny form factor 1.6mm x 1.6mm WLP or 3mm x 3mm TQFN allows for integration into extremely small application devices.
特性
- Biometric Sensor Hub Enables Faster Time to Market
- Finger-Based (Version A) Algorithms Measure:
- Pulse Heart Rate
- Pulse Blood Oxygen Saturation (SpO₂)
- Wrist-Based (Version B) Algorithm Measures:
- Pulse Heart Rate
- Wrist-Based or Ear-Based (Version C) Algorithms Measure:
- Pulse Heart Rate
- Pulse Blood Oxygen Saturation (SpO₂)
- Finger-Based (Version D) Algorithms Measure:
- Pulse Heart Rate
- Pulse Blood Oxygen Saturation (SpO₂)
- Estimated Blood Pressure
- Both Raw and Processed Data Are Available
- Basic Peripheral Mix Optimizes Size and Performance
- One Slave I2C for Communication with a Host Microcontroller
- One Master I2C for Communication with Sensors (Versions A, C, and D)
- One Master SPI for Communication with Sensors (Versions B and C)
- 32.768kHz RTC
- FIFO Provides Minimal Host Interaction
- Bootloader Facilitates Secure, Authenticated Firmware Upgrades
應用領域
- Wearable Fitness
- Hearables
- Wearable Medical
- Portable Medical
- Mobile Devices
產品規格
| 類型 | 描述 | |
|---|---|---|
| 類別 | Integrated Circuits (ICs)/Interface/Sensor and Detector Interfaces | |
| 製造商 | MAXIM | |
| 包裝 | TQFN-24(3x3) | |
| Operating Temperature | -40℃~+105℃ | |
| Voltage - Supply | 1.71V~3.63V | |
| Interface | I2C | |
| Length | 3mm | |
| Width | 3mm | |
| Height | 0.75mm |
| 類型 | 描述 | |
|---|---|---|
| 類別 | Integrated Circuits (ICs)/Interface/Sensor and Detector Interfaces | |
| 製造商 | MAXIM | |
| 包裝 | TQFN-24(3x3) | |
| Operating Temperature | -40℃~+105℃ | |
| Voltage - Supply | 1.71V~3.63V |
| 類型 | 描述 | |
|---|---|---|
| Interface | I2C | |
| Length | 3mm | |
| Width | 3mm | |
| Height | 0.75mm |
概述
The MAX32664 is a sensor hub family with embedded firmware and world-class algorithms for wearables. It seamlessly enables customer-desired sensor functionality, including communication with Analog Devices' optical sensor solutions and delivering raw or calculated data to the outside world. This is achieved while keeping overall system power consumption in check. The device family interfaces to a microcontroller host through a fast-mode slave I2C interface for access to raw and processed sensor data as well as field updates. A firmware bootloader is also provided.
The MAX32664 Version A supports the MAX30101/ MAX30102 high-sensitivity pulse oximeter and heart-rate sensor for wearable health for finger-based applications. A master mode I2C interface for communication with sensors is provided.
The MAX32664 Version B supports the MAX86140/ MAX86141 for wrist-based applications. A master mode SPI interface for communication with sensors is provided.
The MAX32664 Version C supports the MAX86140/ MAX86141 for wrist-based applications and MAXM86161 for ear-based applications. The device provides either a master mode SPI or an I2C interface for communication with sensors.
The MAX32664 Version D supports the MAX30101/ MAX30102 high-sensitivity pulse oximeter and heart-rate sensor for wearable health for finger-based applications. A master mode I2C interface for communication with sensors is provided. Version D also supports estimated blood pressure monitoring.
The wearable algorithms in the MAX32664 sensor hub support a directly connected accelerometer. They also allow feeding of X, Y, and Z samples from a host-connected accelerometer. This architecture provides robust detection and compensation of motion artifacts in captured samples.
The tiny form factor 1.6mm x 1.6mm WLP or 3mm x 3mm TQFN allows for integration into extremely small application devices.
特性
- Biometric Sensor Hub Enables Faster Time to Market
- Finger-Based (Version A) Algorithms Measure:
- Pulse Heart Rate
- Pulse Blood Oxygen Saturation (SpO₂)
- Wrist-Based (Version B) Algorithm Measures:
- Pulse Heart Rate
- Wrist-Based or Ear-Based (Version C) Algorithms Measure:
- Pulse Heart Rate
- Pulse Blood Oxygen Saturation (SpO₂)
- Finger-Based (Version D) Algorithms Measure:
- Pulse Heart Rate
- Pulse Blood Oxygen Saturation (SpO₂)
- Estimated Blood Pressure
- Both Raw and Processed Data Are Available
- Basic Peripheral Mix Optimizes Size and Performance
- One Slave I2C for Communication with a Host Microcontroller
- One Master I2C for Communication with Sensors (Versions A, C, and D)
- One Master SPI for Communication with Sensors (Versions B and C)
- 32.768kHz RTC
- FIFO Provides Minimal Host Interaction
- Bootloader Facilitates Secure, Authenticated Firmware Upgrades
應用領域
- Wearable Fitness
- Hearables
- Wearable Medical
- Portable Medical
- Mobile Devices
C17351452 EasyEDA 元器件庫
合規 & 出口編碼
| 類型 | 詳情 |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | 3A991A2 |
| CNHTS | 8517799000 |
| USHTS | 8517790000 |
| TARIC | 8517790000 |
| CAHTS | 8517790000 |
| BRHTS | 85177900 |
| INHTS | 85177990 |
| MXHTS | 8517.70.99 |
| 類型 | 詳情 |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | 3A991A2 |
| CNHTS | 8517799000 |
| USHTS | 8517790000 |
| TARIC | 8517790000 |
| 類型 | 詳情 |
|---|---|
| CAHTS | 8517790000 |
| BRHTS | 85177900 |
| INHTS | 85177990 |
| MXHTS | 8517.70.99 |



