LCSC Electronics logoLCSC Electronics svg logo
Entrar
USD

TI AFE4300PNR

Fabricante
Cód. da peça
AFE4300PNR
Nº LCSC
C528638
Emb.
LQFP-80(12x12)
Número do Cliente
Atrib. princ.
Low-Cost, Integrated Analog Front-End for Weight-Scale and Body Composition Measurement
Folha de DadosTI AFE4300PNR
Conformidade RoHS2 documentos disponíveis
Peças alternativas1
Garantia em cada pedido
100% Autêntico · Devolução ou Substituição em 30 Dias

Especificações do Produto

Tudo
TipoDescrição
CategoriaIntegrated Circuits (ICs)/Data Acquisition/Analog Front End (AFE)
FabricanteTI
Emb.LQFP-80(12x12)
Clock Frequency-
Interface-
Voltage Reference Value1.7V
Resolution(Bits)16;860Hz
S/N Ratio-
Quiescent Current (Iq)-
Voltage - Supply2V~3.6V
FunctionProgrammable gain;Digital calibration
Operating Temperature0℃~+70℃

Descrição

Tradução por IA

The AFE4300 is a low-cost analog front-end with two independent signal chains: one for body weight scale (WS) measurements and the other for body composition measurement (BCM) analysis. A 16-bit, 860SPS ADC is multiplexed between the two signal chains. The weight measurement signal chain includes an INA with gain set by an external resistor, followed by a 6-bit DAC for offset correction, and a circuit that drives an external bridge/load cell (with a fixed 1.7V voltage for ratiometric measurements). The AFE4300 can also measure body composition by generating a sinusoidal current into the human body. This sinusoidal current is generated by an internal pattern generator and a 6-bit, 1MSPS DAC. A voltage-to-current converter applies this sinusoidal current to the human body across two terminals. The voltage developed across these two terminals is generated by the body's impedance, which is measured by a differential amplifier, then rectified, with its amplitude extracted and measured by the 16-bit ADC. The AFE4300 operates over a supply voltage range of 2V to 3.6V, is rated for 0℃ to +70℃, and is available in an LQFP-80 package.

Recursos

Tradução por IA
  • Up to four load cell inputs supported
  • On-chip load cell 1.7V excitation voltage for ratiometric measurement
  • 68nVrms input-referred noise (0.1Hz to 2Hz)
  • Best-fit linearity: 0.01% of full-scale
  • Body weight measurement: 540μA
  • Up to three tetrapolar bioimpedance measurements supported
  • 6-bit 1MSPS sine wave generation DAC
  • 247.5μArms, ±20% excitation source
  • 0.1Ω measurement RMS noise in 2Hz bandwidth
  • Body composition measurement: 970μA
  • ADC: 16-bit, 860SPS
  • Supply current: 110μA

Aplicações

Tradução por IA
  • Body weight scale with body composition measurement capability