RENERGY RN8302B
| Manufacturer | RENERGYAsian Brands |
| MPN | RN8302B |
| LCSC Part # | C84227 |
| Packaging | LQFP-44(10x10) |
| Customer # | |
| Key Attributes | Three-phase Anti-tampering Multifuction Electircal Energy Meter IC |
| Datasheet |
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/Energy Metering | |
| Manufacturer | RENERGY | |
| Packaging | LQFP-44(10x10) | |
| Clock Frequency | 8.192MHz | |
| Tolerance | 0.1% | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage Reference Value | 1.25V | |
| Voltage - Supply | 3V~3.6V | |
| Dynamic Range | 5000:1 | |
| Function | Programmable gain;Pulse output;Built-in reference source;Energy accumulation engine;Harmonic analysis;Fault detection;Anti-tamper detection;Interrupt control;Digital calibration and compensation | |
| Number of Channels | 7 | |
| Interface | SPI | |
| Meter Type | Polyphase Energy Metering IC | |
| Current - Supply | 5mA |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/Energy Metering | |
| Manufacturer | RENERGY | |
| Packaging | LQFP-44(10x10) | |
| Clock Frequency | 8.192MHz | |
| Tolerance | 0.1% | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage Reference Value | 1.25V |
| Type | Description | |
|---|---|---|
| Voltage - Supply | 3V~3.6V | |
| Dynamic Range | 5000:1 | |
| Function | Programmable gain;Pulse output;Built-in reference source;Energy accumulation engine;Harmonic analysis;Fault detection;Anti-tamper detection;Interrupt control;Digital calibration and compensation | |
| Number of Channels | 7 | |
| Interface | SPI | |
| Meter Type | Polyphase Energy Metering IC | |
| Current - Supply | 5mA |
Introduction
The RN8302B provides full-wave and fundamental active, reactive, and apparent energy and power, supports reactive four-quadrant detection, features creep start functionality, adjustable meter constant, fast pulse counting, and pulse output. It measures full-wave and fundamental power, RMS voltage and current, power factor, line frequency, and phase angle, with zero-crossing detection, phase sequence error detection, and voltage loss indication. Anti-tamper functionality and multiple low-power modes are supported. Software calibration is supported for three-phase three-wire and three-phase four-wire configurations. Powered by a single +3.3V supply with power monitoring, built-in 1.25V ADC reference voltage, high-speed SPI interface, and interrupt output pin. Operating voltage range: 3.0V–3.6V; operating temperature range: -40℃–85℃. Available in LQFP44 green package, compliant with EU RoHS directive. The chip supports four operating modes: metering mode, total voltage loss mode 1, total voltage loss mode 2, and sleep mode. Mode switching is performed via SPI commands, and the default mode after power-on reset is configurable via the PM pin.
Features
- Total-waveform and fundamental active energy measurement; nonlinearity error <0.1% over 5000:1 dynamic range; meets Class 0.5S and Class 0.2S active energy meter accuracy requirements
- Total-waveform and fundamental reactive energy measurement; nonlinearity error <0.1% over 5000:1 dynamic range
- Total-waveform and fundamental apparent energy measurement
- Active and reactive power direction indication; reactive four-quadrant detection
- Anti-creep function with adjustable startup threshold
- Adjustable meter constant
- Fast pulse count output for active, reactive, and apparent energy
- Pulse output for total-waveform and fundamental active, reactive, and apparent energy
- Total-waveform and fundamental active, reactive, and apparent power
- Total-waveform, fundamental, and harmonic three-phase voltage/current RMS values
- Total-waveform and fundamental power factor
- Line frequency measurement; measurement error <0.02%
- Per-phase voltage and current phase angle; measurement error <0.02°
- Seven-channel zero-crossing detection with configurable threshold
- Voltage phase sequence error detection
- Voltage loss indication with configurable threshold
- Flexible voltage and current waveform sample buffer
- Voltage sag detection
- Overvoltage and overcurrent detection
- Neutral current measurement
- Low-power mode NVM2 for current comparison pre-detection; 2-level configurable threshold; power consumption <150μA
- Low-power mode NVM1 for low-power current RMS measurement; power consumption <2mA
- Active full power-loss reporting; typical average power consumption of 7μA
- Seven-channel ADC gain calibration
- Seven-channel ADC phase calibration; Phase A, B, C current channels support segmented phase calibration
- Power gain calibration
- Segmented phase calibration for active and reactive power
- Offset calibration for active power, reactive power, and RMS
- Checksum register with automatic calibration data verification
- Supports three-phase three-wire and three-phase four-wire configurations
- Single +3.3V supply with power monitoring
- Built-in 1.25V ADC voltage reference; typical temperature coefficient 5ppm/℃; external reference supported
- High-speed SPI interface up to 3.5Mbps with write protection
- One interrupt output pin
- Operating voltage range: 3.0V – 3.6V
- Operating temperature range: -40℃ – 85℃
- LQFP44 green package
- Compliant with the test requirements of EU Directive (EU) 2015/863 amending Annex II of RoHS Directive 2011/65/EU
Applications
- Three-phase three-wire meter
- Three-phase four-wire meter
| Qty | Unit Price | Total Amount |
|---|---|---|
| 1+ | $ 2.423 | $ 2.42 |
| 10+ | $ 2.06 | $ 20.60 |
| 30+ | $ 1.831 | $ 54.93 |
| 160+ | $ 1.5067 | $ 241.07 |
| 480+ | $ 1.4019 | $ 672.91 |
| 960+ | $ 1.3551 | $ 1300.90 |
Standard Packaging160/Full Tray | ||
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/Energy Metering | |
| Manufacturer | RENERGY | |
| Packaging | LQFP-44(10x10) | |
| Clock Frequency | 8.192MHz | |
| Tolerance | 0.1% | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage Reference Value | 1.25V | |
| Voltage - Supply | 3V~3.6V | |
| Dynamic Range | 5000:1 | |
| Function | Programmable gain;Pulse output;Built-in reference source;Energy accumulation engine;Harmonic analysis;Fault detection;Anti-tamper detection;Interrupt control;Digital calibration and compensation | |
| Number of Channels | 7 | |
| Interface | SPI | |
| Meter Type | Polyphase Energy Metering IC | |
| Current - Supply | 5mA |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Power Management (PMIC)/Energy Metering | |
| Manufacturer | RENERGY | |
| Packaging | LQFP-44(10x10) | |
| Clock Frequency | 8.192MHz | |
| Tolerance | 0.1% | |
| Operating Temperature | -40℃~+85℃ | |
| Voltage Reference Value | 1.25V |
| Type | Description | |
|---|---|---|
| Voltage - Supply | 3V~3.6V | |
| Dynamic Range | 5000:1 | |
| Function | Programmable gain;Pulse output;Built-in reference source;Energy accumulation engine;Harmonic analysis;Fault detection;Anti-tamper detection;Interrupt control;Digital calibration and compensation | |
| Number of Channels | 7 | |
| Interface | SPI | |
| Meter Type | Polyphase Energy Metering IC | |
| Current - Supply | 5mA |
Introduction
The RN8302B provides full-wave and fundamental active, reactive, and apparent energy and power, supports reactive four-quadrant detection, features creep start functionality, adjustable meter constant, fast pulse counting, and pulse output. It measures full-wave and fundamental power, RMS voltage and current, power factor, line frequency, and phase angle, with zero-crossing detection, phase sequence error detection, and voltage loss indication. Anti-tamper functionality and multiple low-power modes are supported. Software calibration is supported for three-phase three-wire and three-phase four-wire configurations. Powered by a single +3.3V supply with power monitoring, built-in 1.25V ADC reference voltage, high-speed SPI interface, and interrupt output pin. Operating voltage range: 3.0V–3.6V; operating temperature range: -40℃–85℃. Available in LQFP44 green package, compliant with EU RoHS directive. The chip supports four operating modes: metering mode, total voltage loss mode 1, total voltage loss mode 2, and sleep mode. Mode switching is performed via SPI commands, and the default mode after power-on reset is configurable via the PM pin.
Features
- Total-waveform and fundamental active energy measurement; nonlinearity error <0.1% over 5000:1 dynamic range; meets Class 0.5S and Class 0.2S active energy meter accuracy requirements
- Total-waveform and fundamental reactive energy measurement; nonlinearity error <0.1% over 5000:1 dynamic range
- Total-waveform and fundamental apparent energy measurement
- Active and reactive power direction indication; reactive four-quadrant detection
- Anti-creep function with adjustable startup threshold
- Adjustable meter constant
- Fast pulse count output for active, reactive, and apparent energy
- Pulse output for total-waveform and fundamental active, reactive, and apparent energy
- Total-waveform and fundamental active, reactive, and apparent power
- Total-waveform, fundamental, and harmonic three-phase voltage/current RMS values
- Total-waveform and fundamental power factor
- Line frequency measurement; measurement error <0.02%
- Per-phase voltage and current phase angle; measurement error <0.02°
- Seven-channel zero-crossing detection with configurable threshold
- Voltage phase sequence error detection
- Voltage loss indication with configurable threshold
- Flexible voltage and current waveform sample buffer
- Voltage sag detection
- Overvoltage and overcurrent detection
- Neutral current measurement
- Low-power mode NVM2 for current comparison pre-detection; 2-level configurable threshold; power consumption <150μA
- Low-power mode NVM1 for low-power current RMS measurement; power consumption <2mA
- Active full power-loss reporting; typical average power consumption of 7μA
- Seven-channel ADC gain calibration
- Seven-channel ADC phase calibration; Phase A, B, C current channels support segmented phase calibration
- Power gain calibration
- Segmented phase calibration for active and reactive power
- Offset calibration for active power, reactive power, and RMS
- Checksum register with automatic calibration data verification
- Supports three-phase three-wire and three-phase four-wire configurations
- Single +3.3V supply with power monitoring
- Built-in 1.25V ADC voltage reference; typical temperature coefficient 5ppm/℃; external reference supported
- High-speed SPI interface up to 3.5Mbps with write protection
- One interrupt output pin
- Operating voltage range: 3.0V – 3.6V
- Operating temperature range: -40℃ – 85℃
- LQFP44 green package
- Compliant with the test requirements of EU Directive (EU) 2015/863 amending Annex II of RoHS Directive 2011/65/EU
Applications
- Three-phase three-wire meter
- Three-phase four-wire meter
C84227 EasyEDA Library
Compliance & Export Codes
| Type | Details |
|---|---|
| RoHS | |
| ECCN | |
| CNHTS | 8542399000 |
| USHTS | 8542390001 |
| TARIC | 8542399000 |
| CAHTS | 8542390000 |
| BRHTS | 85423999 |
| INHTS | 85423900 |
| MXHTS | 8542.39.99 |
| Type | Details |
|---|---|
| RoHS | |
| ECCN | |
| CNHTS | 8542399000 |
| USHTS | 8542390001 |
| TARIC | 8542399000 |
| Type | Details |
|---|---|
| CAHTS | 8542390000 |
| BRHTS | 85423999 |
| INHTS | 85423900 |
| MXHTS | 8542.39.99 |