XINLUDA XD74LS95
| Manufacturer | XINLUDAAsian Brands |
| MPN | XD74LS95 |
| LCSC Part # | C707076 |
| Packaging | DIP-14 |
| Customer # | |
| Key Attributes | 4-bit Parallel Access Shift Register |
| Datasheet |
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Logic/Shift Registers | |
| Manufacturer | XINLUDA | |
| Packaging | DIP-14 | |
| Operating temperature | -20℃~+75℃ | |
| Pd - Power Dissipation | 400mW | |
| Voltage - Supply | 4.75V~5.25V | |
| Output Type | - | |
| Series | 74LS | |
| Number of Elements | - | |
| Output Current | - | |
| Propagation Delay | 18ns | |
| Features | Asynchronous parallel load function;Supports forward and reverse shift | |
| Function | - |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Logic/Shift Registers | |
| Manufacturer | XINLUDA | |
| Packaging | DIP-14 | |
| Operating temperature | -20℃~+75℃ | |
| Pd - Power Dissipation | 400mW | |
| Voltage - Supply | 4.75V~5.25V | |
| Output Type | - |
| Type | Description | |
|---|---|---|
| Series | 74LS | |
| Number of Elements | - | |
| Output Current | - | |
| Propagation Delay | 18ns | |
| Features | Asynchronous parallel load function;Supports forward and reverse shift | |
| Function | - |
Introduction
The 4-bit register features parallel and serial inputs, parallel outputs, mode control, and two clock inputs. The register has three mode operation: Parallel (broadside) load Shift right (the direction QA toward QD) Shift left (the direction QD toward QA)
Parallel loading is accomplished by applying the four bits of data and taking the mode control input high. The data is loaded into the associated flip - flops and appears at the outputs after the high - to - low transition of the clock - 2 input.
During loading, the entry of serial data is inhibited. Shift right is accomplished on the high - to - low transition of clock - 1 when the mode control is low; shift left is accomplished on the high - to - low transition of clock - 2 when the mode control is high by connecting the output of each flip - flop to the parallel input of the previous flip - flop (QD to input C, etc.) and serial data is entered at input D. The clock input may be applied commonly to clock - 1 and clock - 2 if both modes can be clocked from the same source. Changes at the mode control inputs are low; however, conditions described in the last three lines of the function table will also ensure that register contents are protected.
| Qty | Unit Price | Total Amount |
|---|---|---|
| 5+ | $ 0.2338 | $ 1.17 |
| 50+ | $ 0.1827 | $ 9.14 |
| 150+ | $ 0.1612 | $ 24.18 |
| 500+ | $ 0.1344 | $ 67.20 |
| 2,000+ | $ 0.1225 | $ 245.00 |
| 5,000+ | $ 0.1153 | $ 576.50 |
Standard Packaging25/Full Tube | ||
Products Specifications
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Logic/Shift Registers | |
| Manufacturer | XINLUDA | |
| Packaging | DIP-14 | |
| Operating temperature | -20℃~+75℃ | |
| Pd - Power Dissipation | 400mW | |
| Voltage - Supply | 4.75V~5.25V | |
| Output Type | - | |
| Series | 74LS | |
| Number of Elements | - | |
| Output Current | - | |
| Propagation Delay | 18ns | |
| Features | Asynchronous parallel load function;Supports forward and reverse shift | |
| Function | - |
| Type | Description | |
|---|---|---|
| Category | Integrated Circuits (ICs)/Logic/Shift Registers | |
| Manufacturer | XINLUDA | |
| Packaging | DIP-14 | |
| Operating temperature | -20℃~+75℃ | |
| Pd - Power Dissipation | 400mW | |
| Voltage - Supply | 4.75V~5.25V | |
| Output Type | - |
| Type | Description | |
|---|---|---|
| Series | 74LS | |
| Number of Elements | - | |
| Output Current | - | |
| Propagation Delay | 18ns | |
| Features | Asynchronous parallel load function;Supports forward and reverse shift | |
| Function | - |
Introduction
The 4-bit register features parallel and serial inputs, parallel outputs, mode control, and two clock inputs. The register has three mode operation: Parallel (broadside) load Shift right (the direction QA toward QD) Shift left (the direction QD toward QA)
Parallel loading is accomplished by applying the four bits of data and taking the mode control input high. The data is loaded into the associated flip - flops and appears at the outputs after the high - to - low transition of the clock - 2 input.
During loading, the entry of serial data is inhibited. Shift right is accomplished on the high - to - low transition of clock - 1 when the mode control is low; shift left is accomplished on the high - to - low transition of clock - 2 when the mode control is high by connecting the output of each flip - flop to the parallel input of the previous flip - flop (QD to input C, etc.) and serial data is entered at input D. The clock input may be applied commonly to clock - 1 and clock - 2 if both modes can be clocked from the same source. Changes at the mode control inputs are low; however, conditions described in the last three lines of the function table will also ensure that register contents are protected.
C707076 EasyEDA Library
Compliance & Export Codes
| Type | Details |
|---|---|
| RoHS | |
| ECCN | |
| CNHTS | 8542399000 |
| USHTS | 8542390001 |
| TARIC | 8542399000 |
| CAHTS | 8542390000 |
| BRHTS | 85423999 |
| INHTS | 85423900 |
| MXHTS | 8542.39.99 |
| Type | Details |
|---|---|
| RoHS | |
| ECCN | |
| CNHTS | 8542399000 |
| USHTS | 8542390001 |
| TARIC | 8542399000 |
| Type | Details |
|---|---|
| CAHTS | 8542390000 |
| BRHTS | 85423999 |
| INHTS | 85423900 |
| MXHTS | 8542.39.99 |



