Schneider XMLR010G1N25
| Producent | |
| Nr części prod. | XMLR010G1N25 |
| Nr LCSC | C7397210 |
| Opak. | - |
| Numer Klienta | |
| Klucz. cechy | 80Kpa~1Mpa Pressure Sensors, Transducers - Industrial |
| Karta Katalogowa | Schneider XMLR010G1N25 |
Specyfikacje Produktu
Wszystko
| Typ | Opis | |
|---|---|---|
| Kategoria | Industrial Automation and Controls/Industrial Sensors/Pressure Sensors, Transducers - Industrial | |
| Producent | Schneider | |
| Opak. | - | |
| Absolute Accuracy | - | |
| Pressure range | 80Kpa~1Mpa | |
| Relative Accuracy | - | |
| Features | - | |
| Module | Yes | |
| Voltage - Supply | 17V~33V | |
| Response time | 10ms | |
| Temperature Coefficient of Offset(TCO) | - |
| Typ | Opis | |
|---|---|---|
| Kategoria | Industrial Automation and Controls/Industrial Sensors/Pressure Sensors, Transducers - Industrial | |
| Producent | Schneider | |
| Opak. | - | |
| Absolute Accuracy | - | |
| Pressure range | 80Kpa~1Mpa | |
| Relative Accuracy | - |
| Typ | Opis | |
|---|---|---|
| Features | - | |
| Module | Yes | |
| Voltage - Supply | 17V~33V | |
| Response time | 10ms | |
| Temperature Coefficient of Offset(TCO) | - |
Pomoc i opiniePokaż podobne produkty (0) >
Opis
Tłumaczenie AI
- Fluid inlet: G 1/4 A female thread.
- Analog output signal with I output or V output.
- Offset compensation of ±5% of nominal pressure (via Cof configuration menu; Cof = offset compensation).
- Analog curve adjustable from -25% to +25% of nominal pressure (via AEP configuration menu; AEP = analog endpoint).
- Hysteresis switching mode typically used for "pumping and/or evacuation applications."
- Window switching mode typically used for "pressure regulation applications."
- Time delay typically used to filter rapid pressure transients; output switches only after adjustable time delays "dS" and "dr" (0 to 50 seconds).
Funkcje
Tłumaczenie AI
- Fluid inlet: G 1/4 A female thread
- Analog output: I output or V output
- Compensates offset of ±5% of nominal pressure
- Analog curve adjustable within -25% ~ +25% of nominal pressure
- Hysteresis switching mode for pumping and/or evacuation applications
- Window switching mode for pressure regulation applications
- Time delay for filtering rapid pressure transients; output switching time adjustable from 0 to 50 seconds
Zastosowania
Tłumaczenie AI
Pumping and/or evacuation applications, pressure regulation applications
Gwarancja na każde zamówienie
100% Oryginalne · Zwrot lub Wymiana w ciągu 30 Dni
Specyfikacje Produktu
Wszystko
| Typ | Opis | |
|---|---|---|
| Kategoria | Industrial Automation and Controls/Industrial Sensors/Pressure Sensors, Transducers - Industrial | |
| Producent | Schneider | |
| Opak. | - | |
| Absolute Accuracy | - | |
| Pressure range | 80Kpa~1Mpa | |
| Relative Accuracy | - | |
| Features | - | |
| Module | Yes | |
| Voltage - Supply | 17V~33V | |
| Response time | 10ms | |
| Temperature Coefficient of Offset(TCO) | - |
| Typ | Opis | |
|---|---|---|
| Kategoria | Industrial Automation and Controls/Industrial Sensors/Pressure Sensors, Transducers - Industrial | |
| Producent | Schneider | |
| Opak. | - | |
| Absolute Accuracy | - | |
| Pressure range | 80Kpa~1Mpa | |
| Relative Accuracy | - |
| Typ | Opis | |
|---|---|---|
| Features | - | |
| Module | Yes | |
| Voltage - Supply | 17V~33V | |
| Response time | 10ms | |
| Temperature Coefficient of Offset(TCO) | - |
Pomoc i opiniePokaż podobne produkty (0) >
Opis
Tłumaczenie AI
- Fluid inlet: G 1/4 A female thread.
- Analog output signal with I output or V output.
- Offset compensation of ±5% of nominal pressure (via Cof configuration menu; Cof = offset compensation).
- Analog curve adjustable from -25% to +25% of nominal pressure (via AEP configuration menu; AEP = analog endpoint).
- Hysteresis switching mode typically used for "pumping and/or evacuation applications."
- Window switching mode typically used for "pressure regulation applications."
- Time delay typically used to filter rapid pressure transients; output switches only after adjustable time delays "dS" and "dr" (0 to 50 seconds).
Funkcje
Tłumaczenie AI
- Fluid inlet: G 1/4 A female thread
- Analog output: I output or V output
- Compensates offset of ±5% of nominal pressure
- Analog curve adjustable within -25% ~ +25% of nominal pressure
- Hysteresis switching mode for pumping and/or evacuation applications
- Window switching mode for pressure regulation applications
- Time delay for filtering rapid pressure transients; output switching time adjustable from 0 to 50 seconds
Zastosowania
Tłumaczenie AI
Pumping and/or evacuation applications, pressure regulation applications
Zgodność & Kody Eksportowe
| Typ | Szczegóły |
|---|---|
| ECCN | EAR99 |
| CNHTS | 9026201090 |
| USHTS | 9026204000 |
| TARIC | 9026208000 |
| CAHTS | 9026200090 |
| BRHTS | 90262010 |
| INHTS | 90262000 |
| MXHTS | 9026.20.99 |
| Typ | Szczegóły |
|---|---|
| ECCN | EAR99 |
| CNHTS | 9026201090 |
| USHTS | 9026204000 |
| TARIC | 9026208000 |
| Typ | Szczegóły |
|---|---|
| CAHTS | 9026200090 |
| BRHTS | 90262010 |
| INHTS | 90262000 |
| MXHTS | 9026.20.99 |