OMRON S8FS-G05012CD
| Produttore | |
| Cod. Prod. | S8FS-G05012CD |
| Cod. LCSC | C22405274 |
| Imballo | - |
| Numero Cliente | |
| Attr. chiave | Industrial, DIN Rail Power Supplies RoHS |
| Scheda Tecnica | OMRON S8FS-G05012CD |
| Conformità RoHS | 1 documenti disponibili |
Specifiche del Prodotto
Tutto
| Tipo | Descrizione | |
|---|---|---|
| Categoria | Power Supplies/Power Supplies - External/Internal (Off-Board)/Industrial, DIN Rail Power Supplies | |
| Produttore | OMRON | |
| Imballo | - | |
| Features | Overload protection;Overvoltage Protection |
| Tipo | Descrizione | |
|---|---|---|
| Categoria | Power Supplies/Power Supplies - External/Internal (Off-Board)/Industrial, DIN Rail Power Supplies | |
| Produttore | OMRON |
| Tipo | Descrizione | |
|---|---|---|
| Imballo | - | |
| Features | Overload protection;Overvoltage Protection |
Aiuto & FeedbackMostra prodotti simili (0) >
Caratteristiche
Traduzione AI
- Superior basic performance that ensures reliability Ambient temperatures up to 70°C, greater resistance to rusting with aluminum/stainless steel case, and applications at altitudes up to 3,000 m
- Certification for Global Standards North America: UL 508 (Listing), CSA C22.2 Europe: Overvoltage Category III (EN 50178) EMI: Class B (EN 61204-3) No need for control circuit transformers for which the Machinery Directive is specified. (EN/IEC 61558-2-16)
- The Terminal Block Cover prevents screws from dropping out and the Front Cover prevents ingress of foreign matter
- The input voltage range for compliance with EC Directives and other safety standards (UL, EN, etc.) is 90 to 264 VAC
- EN/IEC 61558-2-16 To comply with EN/IEC 60204-1 (Machine Safety), a transformer is required in the control circuit. If, however, a Power Supply that has a builtin transformer that complies with EN/IEC 6155-8-2-16 is used, an external transformer is not required
- Safety standard targets during a DC input: During a DC input, UL 62368-1, cUR (CSA C22.2 No. 62368-1), EN/IEC 62368-1, EN 50178, EN/IEC 61558-2-16, and EN/IEC 60204-1 are safety standard targets. (However, the input voltage range is 120 to 320 VDC. The safety standards during DC input are not acquired for the S8FS-G60048@.) It is possible to comply with the safety standards by connecting a UL-authenticated fuse
- To comply with the PELV output of the EN/IEC 60204-1, ground the output negative side (-V) to PE
Garanzia su ogni ordine
100% Autentico · Reso o Sostituzione entro 30 Giorni
Specifiche del Prodotto
Tutto
| Tipo | Descrizione | |
|---|---|---|
| Categoria | Power Supplies/Power Supplies - External/Internal (Off-Board)/Industrial, DIN Rail Power Supplies | |
| Produttore | OMRON | |
| Imballo | - | |
| Features | Overload protection;Overvoltage Protection |
| Tipo | Descrizione | |
|---|---|---|
| Categoria | Power Supplies/Power Supplies - External/Internal (Off-Board)/Industrial, DIN Rail Power Supplies | |
| Produttore | OMRON |
| Tipo | Descrizione | |
|---|---|---|
| Imballo | - | |
| Features | Overload protection;Overvoltage Protection |
Aiuto & FeedbackMostra prodotti simili (0) >
Caratteristiche
Traduzione AI
- Superior basic performance that ensures reliability Ambient temperatures up to 70°C, greater resistance to rusting with aluminum/stainless steel case, and applications at altitudes up to 3,000 m
- Certification for Global Standards North America: UL 508 (Listing), CSA C22.2 Europe: Overvoltage Category III (EN 50178) EMI: Class B (EN 61204-3) No need for control circuit transformers for which the Machinery Directive is specified. (EN/IEC 61558-2-16)
- The Terminal Block Cover prevents screws from dropping out and the Front Cover prevents ingress of foreign matter
- The input voltage range for compliance with EC Directives and other safety standards (UL, EN, etc.) is 90 to 264 VAC
- EN/IEC 61558-2-16 To comply with EN/IEC 60204-1 (Machine Safety), a transformer is required in the control circuit. If, however, a Power Supply that has a builtin transformer that complies with EN/IEC 6155-8-2-16 is used, an external transformer is not required
- Safety standard targets during a DC input: During a DC input, UL 62368-1, cUR (CSA C22.2 No. 62368-1), EN/IEC 62368-1, EN 50178, EN/IEC 61558-2-16, and EN/IEC 60204-1 are safety standard targets. (However, the input voltage range is 120 to 320 VDC. The safety standards during DC input are not acquired for the S8FS-G60048@.) It is possible to comply with the safety standards by connecting a UL-authenticated fuse
- To comply with the PELV output of the EN/IEC 60204-1, ground the output negative side (-V) to PE
Conformità & Codici di Esportazione
| Tipo | Dettagli |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | EAR99 |
| CNHTS | 8504902000 |
| USHTS | 8504909690 |
| TARIC | 8504909000 |
| CAHTS | 8504909090 |
| BRHTS | 85049020 |
| INHTS | 85049090 |
| MXHTS | 8504.90.99 |
| Tipo | Dettagli |
|---|---|
| RoHS | ROHS3 Compliant |
| ECCN | EAR99 |
| CNHTS | 8504902000 |
| USHTS | 8504909690 |
| TARIC | 8504909000 |
| Tipo | Dettagli |
|---|---|
| CAHTS | 8504909090 |
| BRHTS | 85049020 |
| INHTS | 85049090 |
| MXHTS | 8504.90.99 |