Walter Elec TE-18710A250T001BG
| 제조업체 | Walter ElecAsian Brands |
| 제조사 품번 | TE-18710A250T001BG |
| LCSC 번호 | C435436 |
| 포장 | Through Hole,D4.3xL11mm |
| 고객 번호 | |
| 주요 제원 | 187℃ 250V 10A 154℃ 181.5℃ Through Hole,D4.3xL11mm Thermal Cutoffs (Thermal Fuses) |
| 데이터시트 | Walter Elec TE-18710A250T001BG |
제품 사양
전체
| 타입 | 설명 | |
|---|---|---|
| 카테고리 | Circuit Protection/Thermal Cutoffs (Thermal Fuses) | |
| 제조업체 | Walter Elec | |
| 포장 | Through Hole,D4.3xL11mm | |
| Rated Functioning Temperature | 187℃ | |
| Voltage Rating | 250V | |
| Current Rating | 10A | |
| Maximum Temperature Limit | 300℃ | |
| Holding Temperature | 154℃ | |
| Operating Temperature | 181.5℃ | |
| Type | Plug-in |
| 타입 | 설명 | |
|---|---|---|
| 카테고리 | Circuit Protection/Thermal Cutoffs (Thermal Fuses) | |
| 제조업체 | Walter Elec | |
| 포장 | Through Hole,D4.3xL11mm | |
| Rated Functioning Temperature | 187℃ | |
| Voltage Rating | 250V |
| 타입 | 설명 | |
|---|---|---|
| Current Rating | 10A | |
| Maximum Temperature Limit | 300℃ | |
| Holding Temperature | 154℃ | |
| Operating Temperature | 181.5℃ | |
| Type | Plug-in |
도움말 및 피드백유사 제품 보기 (0) >
주요 특징
AI 번역
- Tensile force: The thermal fuse sample is supported in any convenient manner without causing damage; a tensile force of 15.7N is applied to each lead for 1 minute — no lead shall crack or break
- Push force: The thermal fuse sample is supported in any convenient manner without causing damage; a push force of 3.9N is applied to each lead for 1 minute — no lead shall crack or break
- Torsional force: The thermal fuse sample is supported in any convenient manner without causing damage; each lead is bent 90° at a point 10mm from the thermal fuse body, then twisted 180° — no lead shall crack or break
- Vertical pressure: The pressure applied vertically to the thermal fuse body housing shall be ≤10kgf (98N)
- Rated operating temperature: The temperature at which the thermal fuse changes its conductive state under a test current load of no more than 10mA; temperature tolerance within +0, -10°C
- Actual operating temperature: The temperature at which the thermal fuse operates in an oven at a heating rate of 0.5~1°C/min with a detection current not exceeding 10mA
- Holding temperature: The maximum temperature a thermal fuse can withstand without changing its electrical conductive state while carrying rated current continuously for 168 hours
- Maximum limiting temperature: The maximum temperature at which the thermal fuse may be exposed after it has changed its electrical conductivity; the thermal fuse sustains this elevated temperature for 10 minutes without degradation of mechanical or electrical characteristics
- Storage conditions: Temperature -10°C~40°C, relative humidity ≤75% (annual average); maximum relative humidity 95% for up to 30 days, condensation-free
- Insulation resistance: Using a DC voltage equal to twice the rated voltage as the test voltage, the insulation resistance across the open contacts shall be at least 0.2MΩ, and the insulation resistance between current-carrying contacts and the housing shall be at least 2MΩ
- High voltage withstand test: Between current-carrying contacts, the thermal fuse shall withstand twice the rated voltage for more than 1 minute; between live parts and the housing, the thermal fuse shall withstand twice the rated voltage + 1000V for more than 1 minute
응용 분야
AI 번역
- General electro-chemical products
- Electric heating products
- Kitchen appliances
- Motors and coil-type products
모든 주문 보장
100% 정품 · 30일 반품 또는 교환
제품 사양
전체
| 타입 | 설명 | |
|---|---|---|
| 카테고리 | Circuit Protection/Thermal Cutoffs (Thermal Fuses) | |
| 제조업체 | Walter Elec | |
| 포장 | Through Hole,D4.3xL11mm | |
| Rated Functioning Temperature | 187℃ | |
| Voltage Rating | 250V | |
| Current Rating | 10A | |
| Maximum Temperature Limit | 300℃ | |
| Holding Temperature | 154℃ | |
| Operating Temperature | 181.5℃ | |
| Type | Plug-in |
| 타입 | 설명 | |
|---|---|---|
| 카테고리 | Circuit Protection/Thermal Cutoffs (Thermal Fuses) | |
| 제조업체 | Walter Elec | |
| 포장 | Through Hole,D4.3xL11mm | |
| Rated Functioning Temperature | 187℃ | |
| Voltage Rating | 250V |
| 타입 | 설명 | |
|---|---|---|
| Current Rating | 10A | |
| Maximum Temperature Limit | 300℃ | |
| Holding Temperature | 154℃ | |
| Operating Temperature | 181.5℃ | |
| Type | Plug-in |
도움말 및 피드백유사 제품 보기 (0) >
주요 특징
AI 번역
- Tensile force: The thermal fuse sample is supported in any convenient manner without causing damage; a tensile force of 15.7N is applied to each lead for 1 minute — no lead shall crack or break
- Push force: The thermal fuse sample is supported in any convenient manner without causing damage; a push force of 3.9N is applied to each lead for 1 minute — no lead shall crack or break
- Torsional force: The thermal fuse sample is supported in any convenient manner without causing damage; each lead is bent 90° at a point 10mm from the thermal fuse body, then twisted 180° — no lead shall crack or break
- Vertical pressure: The pressure applied vertically to the thermal fuse body housing shall be ≤10kgf (98N)
- Rated operating temperature: The temperature at which the thermal fuse changes its conductive state under a test current load of no more than 10mA; temperature tolerance within +0, -10°C
- Actual operating temperature: The temperature at which the thermal fuse operates in an oven at a heating rate of 0.5~1°C/min with a detection current not exceeding 10mA
- Holding temperature: The maximum temperature a thermal fuse can withstand without changing its electrical conductive state while carrying rated current continuously for 168 hours
- Maximum limiting temperature: The maximum temperature at which the thermal fuse may be exposed after it has changed its electrical conductivity; the thermal fuse sustains this elevated temperature for 10 minutes without degradation of mechanical or electrical characteristics
- Storage conditions: Temperature -10°C~40°C, relative humidity ≤75% (annual average); maximum relative humidity 95% for up to 30 days, condensation-free
- Insulation resistance: Using a DC voltage equal to twice the rated voltage as the test voltage, the insulation resistance across the open contacts shall be at least 0.2MΩ, and the insulation resistance between current-carrying contacts and the housing shall be at least 2MΩ
- High voltage withstand test: Between current-carrying contacts, the thermal fuse shall withstand twice the rated voltage for more than 1 minute; between live parts and the housing, the thermal fuse shall withstand twice the rated voltage + 1000V for more than 1 minute
응용 분야
AI 번역
- General electro-chemical products
- Electric heating products
- Kitchen appliances
- Motors and coil-type products
C435436 EasyEDA 라이브러리
컴플라이언스 & 수출 코드
| 타입 | 세부사항 |
|---|---|
| ECCN | |
| CNHTS | 8536100000 |
| USHTS | 8536100040 |
| TARIC | 8536109010 |
| CAHTS | 8536100000 |
| BRHTS | 85361000 |
| INHTS | 85361010 |
| MXHTS | 8536.10.01 |
| 타입 | 세부사항 |
|---|---|
| ECCN | |
| CNHTS | 8536100000 |
| USHTS | 8536100040 |
| TARIC | 8536109010 |
| 타입 | 세부사항 |
|---|---|
| CAHTS | 8536100000 |
| BRHTS | 85361000 |
| INHTS | 85361010 |